background image

User Manual 

RANGE HOOD | 

PRISMA ISLA 90 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.  CIRCUIT DIAGRAM 

 

 

Summary of Contents for Prisma Isla 90

Page 1: ......

Page 2: ...User Manual RANGE HOOD PRISMA ISLA 90 2 1 SAFETY NOTIFICATIONS 3 2 INSTRUCTION FOR THE SWITCH 4 3 INSTALLATION SKETCH 5 4 CIRCUIT DIAGRAM 7 5 TROUBLE SHOOTING 8 6 CLEANING MAINTENANCE 8 ...

Page 3: ...ing just the power cord do not yank out the plug by pulling on the power cord Risk of electric shock and fire Please use an earthed 220V 240V outlet Risk of damage and electric shock Make sure not to overload the outlet Risk of excessive heat and fire Do not touch the plug with wet hands Clean the plug if is moist or dusty Risk of electric shock Do not let children use the hood Risk of personal in...

Page 4: ...um high stop in the sequence cycle When the chimney bell is in standby mode press the key then the bell rings and the halo indicator light is blue the engine runs at high speed Each time you press this button the speed has been high medium low stop in the sequence cycle Time key When the chimney campaign is in standby mode press the activation key the buzzer sounds and the halo indicator light is ...

Page 5: ...User Manual RANGE HOOD PRISMA ISLA 90 5 3 INSTALLATION SKETCH ...

Page 6: ...User Manual RANGE HOOD PRISMA ISLA 90 6 ...

Page 7: ...User Manual RANGE HOOD PRISMA ISLA 90 7 4 CIRCUIT DIAGRAM ...

Page 8: ...and or service office 2 Contact the distributor and or service office Insufficient suction 1 The vents on the outlet cover not open completely 2 There is too much airflow around the machine 3 The oil filter is too dirty 4 The wire and or cable damaged 1 Lower the machine check the vents and loosen them 2 Close any open windows 3 Clean it 4 Have a mechanic fix it 6 CLEANING AND MAINTENANCE Never us...

Page 9: ...is filter will catch the odor and should be changed at least once a year depending on how much it is underneath Order these filters from your dealer using the nameplate reference number inside the extractor and keep a note of the date it was changed WARNING 1 Disconnect the extractor before performing any service 2 Remove the filters 3 Insert the new carbon filter into the fan extractor 4 On the i...

Page 10: ...2W LED by unscrewing 3 Replace the assembly by performing the operations in reverse order MODEL USING BULB LIGHTS OR NEON TUBE 1 Unscrew the screw securing the light cover 2 Tilt back 3 The type of bulb you use is 2W LED replace the bulb unscrew and screw the new bulb see diagram 4 Replace the light cover screw the light cover back on ...

Page 11: ...User Manual RANGE HOOD PRISMA ISLA 90 11 ...

Reviews: