• Fastening the suspension hook and flange.
Fixing the suspension hook.
Drill into the wall 3 holes of 8mm and depth 50mm and insert into the holes three
expansion plugs. Use 3 ST5x50 screws to attach the suspension hook to the wall
(see fig.2.3 below).
Fastening the flange
Drill into the wall 4 holes (2 holes per flange) of 8mm and depth 50mm and insert
into the holes 4 expansion plugs. Use 4 screws ST5x50 to fix flange A and flange
B. to the wall (see figures 2.1 and 2.2 below).
• Installation of plastic spacer and exhaust duct. Assembly of the body of the fat
extractor.
Use 2 M4x10 screws to attach the plastic spacers to the grease extractor body
(see figure 3).
Mounting the extractor body to the wall.
Use 2 ST4x8 screws to screw the exhaust duct into the exhaust outlet of the
grease extractor.