Page 7
Installation manual - Outback Chef Wood Burning Cookstove
ENGLISH
Appliance clearances with or
without lid
(single wall pipe)
CANADA
USA
A
15" (381 mm)
11" (279 mm)
B
9" (229 mm)
9" (229 mm)
C
48" (1219 mm)
36 " (914 mm)
L
84" (2134 mm)
84" (2134 mm)
Appliance clearances without lid
(double wall pipe)
CANADA
USA
A
14" (356 mm)
11" (279 mm)
B
9" (229 mm)
9" (229 mm)
C
48" (1219 mm)
36" (914 mm)
L
84 "(2134 mm)
84" (2134 mm)
Appliance clearances with lid
(double wall pipe)
CANADA
USA
A
7" (178 mm)
7" (178 mm)
B
9" (229 mm)
9" (229 mm)
C
48" (1219 mm)
36" (914 mm)
L
84" (2134 mm)
84" (2134 mm)
Appliance clearances with lid and heat
shield screen
(double wall pipe)
CANADA
USA
A
3" (76 mm)
3" (76 mm)
B
5" (127 mm)
5" (127 mm)
C
48" (1219 mm)
36" (914 mm)
L
84" (2134 mm)
84" (2134 mm)
E
B
D
A
C
Pipe connector distance*
(single wall pipe)
CANADA
USA
D
18" (457 mm)
14" (356 mm)
E
35 ½" (902 mm)
35 ½" (902 mm)
Pipe connector distance*
(double wall pipe)
CANADA
USA
D
17" (432 mm)
14" (356 mm)
E
35 ½" (902 mm)
35 ½" (902 mm)
*Note that the appliance clearances and the pipe distances must be met individually. It is, however, possible to reduce the appliance
clearances by using a heat shield screen. The clearance for a single wall pipe is 18". For the clearance of a double wall certified pipe,
refer to the pipe manufacturer’s approval plate.