2.3 Non-authorized configuration, Canada and United States
- The hot air duct
(A)
must not be
installed in the air return of
(B)
.
- The hot air duct
(B)
must not be
installed in the air return of
(A)
.
3 Setting up the unit and clearances
To reduce the risk of vibration, the furnace must be leveled in both directions and
supported evenly to ensure stability.
3.1 Unit location
The furnace must be installed in a location:
-
Where outside air supply will be sufficient for proper combustion;
-
Where connector is as short as possible in order to minimize the use of 90
o
elbows
and horizontal lengths;
-
That ensure a proper installation and safe operation of the appliance;
-
Where the owner can ensure cleanliness of the room in the event of negative
pressure or temporarily negative;
-
Where room to perform maintenance is sufficient and safe.
3.2 Certification label
N.B.: THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE
INSTRUCTIONS ON THE CERTIFICATION LABEL APPLIED ON THE UNIT.
Location:
You will find the certification label on the back of the appliance.
Information found on the certification label always overrides the information published in
any other publication.
Content of certification label:
Model number, serial number, certification agency,
Standards, clearances to combustible material, as well as the main safety cautions.
Summary of Contents for DF01001
Page 30: ...HeatMax II Furnace Installation and Operation Manual 30 ...
Page 64: ...HeatMax II Furnace Installation and Operation Manual 64 11 Exploded diagram and parts list ...
Page 65: ...HeatMax II Furnace Installation and Operation Manual 65 ...
Page 66: ...HeatMax II Furnace Installation and Operation Manual 66 ...
Page 67: ...HeatMax II Furnace Installation and Operation Manual 67 ...
Page 68: ...HeatMax II Furnace Installation and Operation Manual 68 ...
Page 74: ...HeatMax II Furnace Installation and Operation Manual 74 12 2 1 Technical data HeatMax II ...
Page 75: ...HeatMax II Furnace Installation and Operation Manual 75 ...