Page 7
OPERATION MANUAL ECO-55 / ECO-55 ST
ENGLISH
CAUTION
KEEP HOPPER LID CLOSED AT ALL TIMES
EXCEPT WHEN REFUELING.
5.4 SHUT DOWN
To turn the stove off, press the «MODE» button until
the red light is in the OFF position. The cooling cycle
will take a few minutes. The blowers will continue to
work while the stove is cooling down.
NOTICE
Never disconnect the power cord to turn off the
stove.
A thermostat may help maintaining a stable room
temperature automatically. A Low voltage thermostat
is required. A fixed wall mount or hand held model
can be used.
To use the thermostat mode, press the «MODE»
button until you reach the «THERMOSTAT» position.
Then select the intensity level using the «-» or
«+» buttons. In thermostatic mode, the stove will
operate at the selected intensity level until the room
temperature has reached the programmed level on
the thermostat.
5.5.1 PILOT MODE SELECTION
The factory setting of the pilot mode is AUTO. To
change it, press on the «-» and «MODE» buttons
simultaneously for 3 seconds. The selected mode will
appear on the control panel display area.
Pilot AUTO (Intensity level 1):
When the thermostat
stops requiring heat, the unit will remain at its lowest
intensity level (#1) and will shut down after 15
minutes, if there is no demand for heat.
Pilot AUTO (Intensity level 2 to 6):
When the thermostat
stops requiring heat, the unit automatically switch
to its lowest intensity level (#1) until the thermostat
requires heat again. The stove will shut down after 45
minutes, if there is no demand for heat.
Pilot ON:
When the thermostat stops requiring heat,
the unit automatically switch to its lowest intensity
level (#1) until the thermostat requires heat again.
The stove will never shut down, even if there is no
demand for heat.
5.6 THERMOSTAT MODE
5.5 SIGNS OF OVERHEATING
If the stove is overheating, it will become very hot and
will shut itself down, showing an H error code. If this
occurs, wait for the stove to cool down and perform
the weekly maintenance of the stove suggested in
the maintenance calendar. Carefully inspect the
venting system. Have it swept, if necessary. Press on
the «MODE» and «RESET» buttons simultaneously
for 3 seconds to reset the stove.
After three H code occurence, the stove control will
be locked and it will be impossible to reset it and
restart the stove. Before unlocking the stove control,
perform the biannual maintenance suggested in the
maintenance calendar. Carefully inspect the venting
system. Have it swept, if necessary.
When maintenance is done, press the following
buttons, one at a time : «RESET», «MODE», «+»,
«-», then press on the «AUGER» for 5 seconds.
DANGER
IF ANY EXTERNAL PART OF THE STOVE
BEGINS TO GLOW RED, THE STOVE IS
OVERHEATING. IMMEDIATELY TURN THE
STOVE OFF. DO NOT UNPLUG IT AND DO
NOT OPEN THE DOOR. UNPLUGING THE
STOVE WILL DISABLE ALL THE SAFETY
FEATURES OF THE STOVE.
DANGER
AN OVERHEATING STOVE MAY LEAD TO A
HOUSE FIRE. EACH H CODE SHOULD BE
FOLLOWED BY A STOVE MAINTENANCE
AND A VENTING SYSTEM VERIFICATION.