Eco-65 Installation and Operation Manual
29
Control panel screen
Operation mode :
OFF
MANUAL
THERMOSTAT:
Thermostatic control
(optional)
Button to select
between modes
Button to clear
most error codes
Button to change the
convection fan speeds
Button to feed and start
when the auger is empty
Pellet burn rate
and – allows
to select the heat level
5.1.1 Mode Button
When the mode switch is pressed, you will be able to choose the Manual or the Thermostat
mode, or to turn off the appliance. If the Manual mode is selected, the stove will automatically
ignite. At this time, the heat level must be selected manually to adjust the stove’s heat output
to the desired level. If the thermostat mode is selected, the stove will automatically modulate
between the lowest heat level and the heat level selected to keep the room temperature at
the thermostat’s setting (see
Section 6.6.1: Pilot mode selection
).
No fire starter is
necessary to ignite the unit. The auger will feed fuel and the electric igniter will start. If the
unit doesn’t ignite within 12 minutes, the stove will start another ignition cycle. If ignition fails
a second time, a warning message will appear on the control panel.
The Heat Level may be selected during the ignition cycle. However, the unit will only feed fuel
at the desired heat level setting when the heat sensor located into the stove will receive a
signal indicating that the unit has been fully ignited. This may take anywhere between 10 and
15 minutes.
Summary of Contents for ECO-65
Page 67: ...Eco 65 Installation and Operation Manual 67 9 Wiring Diagram ...
Page 79: ...Eco 65 Installation and Operation Manual 79 14 Exploded View and Replacement Parts SECTION A ...
Page 80: ...Eco 65 Installation and Operation Manual 80 SECTION B ...
Page 81: ...Eco 65 Installation and Operation Manual 81 SECTION C ...
Page 82: ...Eco 65 Installation and Operation Manual 82 SECTION D SECTION E ...
Page 83: ...Eco 65 Installation and Operation Manual 83 SECTION F SECTION G ...
Page 84: ...Eco 65 Installation and Operation Manual 84 SECTION H SECTION I ...
Page 85: ...Eco 65 Installation and Operation Manual 85 SECTION J ...