Installation and Operation Manual for Escape 1800
22
4.4.6.4 Maximum Burn Cycle Times
The burn cycle time is the period between loading wood on a coal bed and the
consumption of that wood back to a coal bed of the same size. The flaming phase of the
fire lasts for roughly the first half of the burn cycle and the second half is the coal bed
phase during which there is little or no flame. The length of burn you can expect from your
stove, including both the flaming and coal bed phases, will be affected by a number of
things, such as:
•
firebox size,
•
the amount of wood loaded,
•
the species of wood you burn,
•
the wood moisture content,
•
the size of the space to be heated,
•
the climate zone you live in and
•
the time of year.
The table below provides a very general indication of the maximum burn cycle times you
are likely to experience, based on firebox volume.
FIREBOX VOLUME
MAXIMUM
BURN TIME
<1.5 cubic feet
3 to 5 hours
1.5 c.f. to 2.0 c.f
5 to 6 hours
2.0 c.f. to 2.5 c.f.
6 to 8 hours
2.5 c.f. to 3.0 c.f.
8 to 9 hours
>3.0 c.f.
9 to 10 hours
Long burn times are not necessarily an indication of efficient stove operation. When you
are home during the day and able to tend the fire, it is preferable to build a smaller fire that
might provide three or four hours of heating than to fully load the firebox for a much longer
burn. Shorter burn cycles make it easier to match the heat output of the stove to the heat
demand of the space.
4.4.6.5 North-South Fires Versus East-West Fires
In fireboxes that are roughly square, wood can be loaded so that looking through the glass
door you see the ends of the logs (north-south) or the sides of the logs (east-west).
East-west loads that are built compactly break down slowly when heated, but the amount
of wood you can load is limited because if you put in too many pieces, one may fall against
the glass. East-west loads are excellent for long, low output fires for relatively mild
weather.
North-south loads break down more quickly, but much more wood can be loaded at a time.
This makes north-south loading good for high output, long lasting fires for cold weather.
Summary of Contents for Escape 1800 DB03102
Page 8: ...Installation and Operation Manual for Escape 1800 8 Models on pedestal ...
Page 9: ...Installation and Operation Manual for Escape 1800 9 Models on legs ...
Page 36: ...Installation and Operation Manual for Escape 1800 36 Clearances for shield construction ...
Page 59: ...Installation and Operation Manual for Escape 1800 59 DB03112 DB03113 ...