EXCEL-FIRE GAS STOVE
13
Pilot assembly
Adjusting air shutter (Venturi)
The factory setting for the air shutter is 1/4” for natural gas, fuily open for propane. After operating
the appliance for half an hour or so the flames should have turned a nice yellow colour. However,
in higher altitudes you may find a smudging up of the glass after a few days. The shutter should
then be adjusted open in 1/16” increments until the glass stays clear. If the flame does not turn
yellow the air shutter should be closed until the flame just turns yellow. To access the shutter you
need to remove the glass front, the logs and grate. Lift out the hearth surrounding the burner and
the shutter will be exposed underneath. Loosen the retaining screw 1 turn before attempting to
move the shutter.
OPTIONS
ITEM DESCRIPTION
Part no
•
Wall thermostat kit
AC05558
•
130 CFM blower kit with variable speed control
AC05914
REPLACEMENT PARTS
ITEM DESCRIPTION
Part no
•
6’’ stove pipe adapter
SE9348
•
Set of logs 5
AC05791
•
Burner (natural gas or propane)
SE09311-01
•
Pyroceram Glass (19.446" x 11.737")
SE09335-05
•
1/2
″
dia. gasket for door
40020
•
U gasket for glass
40005
•
Blower 130 cfm
44070
•
Variable speed control
44080
•
Thermo-switch (for blower)
44044
•
Gas valve (natural gas) SIT
49133
•
Gas valve (propane) SIT
49126
•
Pilot assembly (natural gas) SIT
49103
•
Pilot assembly (propane) SIT
49106
•
Piezo igniter
49128
•
Burner orifice (natural gas #36)
9071
•
Burner orifice (propane #52)
9071-01
•
Thermocouple 49122
•
Spill switch
44047
•
Thermopile 49095