8
2.3 Heat output adjustment
The valve supplied with the appliance has a HI/LO knob to control the heat output and flame height
(see Figure 2).
2.4 Fan operation
The fan control knob is located on the control panel and may be adjusted to the following settings:
OFF: Turn the control fully counter-clockwise until the switch operates.
Variable Speed Setting:
Turn the control to the desired setting. When the knob is turned fully clockwise the fan will set to
minimum speed.
Do not use this appliance if any part has been under water. Immediately call a qualified service
technician to inspect the appliance and to replace any part of the control system and any gas controls
which have been under water.
Due to high temperatures, the appliance should be located out of traffic and away from furniture and
draperies.