HeatPack Furnace Installation and Operation Manual
15
Recommended installation
Inside
chimneys
are
recommended
because even when no fire is burning, there
is normally an upward flow in the system.
Not recommended installation
An outside chimney will create problems
because it creates a cold backdraft, if the
furnace is installed in the lower part of the
house.
6.1.2 Masonry chimneys
The furnace may also be connected to a masonry chimney, provided the chimney
complies with the construction rules found in the building code enforced locally.
•
The chimney must have a clay liner.
•
If the masonry chimney has a
square or rectangular liner that is
larger in cross sectional area than a
round 6" (152 mm) flue, it should be
relined with a listed 6" (152 mm)
stainless steel liner.
•
When
passing
through
a
combustible wall, the use of wall
thimble is required.
•
If a stainless steel jacket (liner) is to
be installed, it must extend 12"
(305 mm) to 18" (457 mm) above
the top of the masonry chimney to
improve draught.
6.1.3 Minimum chimney height
The top of the chimney should be tall enough to be above the air turbulence caused when
wind blows against the house and its roof.
•
The chimney must extend at least 3 ft. (1 m) above the highest point of contact with the
roof.
•
Extend at least 2 ft. (61 cm) higher than any roof line or obstacle within a horizontal
distance of 10 ft. (3 m).
Summary of Contents for HeatPack DF00500
Page 29: ...HeatPack Furnace Installation and Operation Manual 29...
Page 64: ...HeatPack Furnace Installation and Operation Manual 64 13 Exploded diagram and parts list...
Page 65: ...HeatPack Furnace Installation and Operation Manual 65...
Page 66: ...HeatPack Furnace Installation and Operation Manual 66...
Page 67: ...HeatPack Furnace Installation and Operation Manual 67...
Page 68: ...HeatPack Furnace Installation and Operation Manual 68...
Page 69: ...HeatPack Furnace Installation and Operation Manual 69...
Page 75: ...HeatPack Furnace Installation and Operation Manual 75 14 2 1 Technical data HeatPack...
Page 76: ...HeatPack Furnace Installation and Operation Manual 76...