HeatPro Furnace Installation and Operation Manual
8
2 Authorized and non-authorized configuration
2.1 Authorized configurations in Canada and United States
The wood furnace is the only appliance
connected to the hot air distribution duct
system and air return duct system.
2.2 Authorized configurations in United States only
Parallel installation :
- (A) represents the wood
furnace.
- (B) represents the gas, oil
or electric existing furnace.
- Power input (B) should be
equal to or greater than (A).
- Each furnace must have its
own air return duct system.
- The highest clearances of
(A and B) and hot air
distribution and air return
ducts of must be respected.
- Static pressure of (A) must
be adjusted to 0.20 in. W.C.
(50 Pa).