Dromone Multi– Lock Quick Coupler
QMS 22
Dromone Multi– Lock Quick Coupler
Author:EOD
REV: D - JAN2012
12
Approved:MS
Bucket/Attachment Release
Before attempting the release of a
bucket or any other attachment it is im-
portant to check for the following.
A.
Ensure that the area within the
maximum machine swing radius
is clear of all personnel and
obstacles.
B.
Put attachment on level ground
to ensure that it does not roll
over.
Procedure:
1.Lower the ‘Quick Coupler and attach-
ment to the ground with the ‘Quick Cou-
pler’ rotated fully inwards towards the
machine in order to disengage the auto-
matic latching system.
2. Press the ’POWER’ button on the in-
cab control panel to the, The visual Led
will pulsate GREEN and activate an audi-
ble buzzer (continuous tone) in the ma-
chine cab (
Figure 12
).
NOTE: If no further action is taken
within 5 seconds the unit will
automatically ‘LOCK OUT’, the
indicators will go out and the green
LED light will return to a constant
green light.
3. Activation of cylinders:
Press the ’CONTROL’ button within 5 sec-
onds from switch on. The status indicator
light will illuminate to a flashing red sig-
nal and the buzzer will also change from
a continuous tone to a pulsating tone.
This indicates that a positive supply is
being sent to the solenoid valve, which in
turn operates the both lock cylinder.
NOTE: After ’CONTROL’ button is
pressed, the system will activate a
warning signal at 55 seconds, and
after 60 seconds the hitch will reset
to a closed position.
Ground
200mm
Fig 11.
Lowering the bucket
Fig 12.
Switching control box on
Fig 13.
Press ’CONTROL’ Button