3.4 Stopping Ignitions Checklist
1
.
Press Stop Dropping button in App
:
Pressed
2
.
Check Ignis Status
:
Idle
3
.
Disarm Ignis
:
Disarmed
3.5 Reloading Between Flights Checklist
1
.
Disarm Ignis
:
Disarmed
2
.
Emergency Release Dials
:
Rotated Counterclockwise, Safe
3
.
Ignis App Ignis Setup
:
Connected
4
.
Ignis Battery Level
:
Greater Than 7.4V
5
.
Reservoir and Pumps
:
Filled and Purged of Air
6
.
Drone Preflight Inspection
:
Completed
7
.
(OPTIONAL) Start Test Ignitions
:
Injecting and Dropping
WARNING: If ignition spheres are loaded in the hopper, this will cause them to be injected
and poses a fire risk. If performing this step, do so under controlled conditions.
8
.
Stop Dropping
:
Disarmed, Ignis Stopped
9
.
Fill Hopper
:
Filled
Note: Use the app “AGITATE” button when filling to ensure chutes are filled
10
.
Ready for Takeoff
:
Ready
3.6 Post Flight Inspection Checklist
1
.
Drone Safe
:
Safe
2
.
Slipper Block
:
Empty
3
.
Ignis Battery
:
Disconnected
4
.
Inspect for Visible Damage
:
No Damage
Last Updated March 12, 2020