Ignis Operations Manual
Drone Amplified
EMERGENCY RELEASE TRIGGERED:
The emergency release has been triggered.
Dropping is disabled until you power-cycle Ignis.
S1 NOT CCW:
(M600 Only) Dropping is disabled because the knob on the control bar
labeled “S1” is not twisted counter-clockwise all the way. This knob is used to trigger the
emergency release, and Ignis will not allow dropping until this knob is ready. An
emergency release is triggered when S1 and S2 are twisted all the way clockwise within
2 seconds of each other.
S2 NOT CCW:
(M600 Only) Dropping is disabled because the knob on the control bar
labeled “S2” is not twisted counter-clockwise all the way. This knob is used to trigger the
emergency release, and Ignis will not allow dropping until this knob is ready. An
emergency release is triggered when S1 and S2 are twisted all the way clockwise within
2 seconds of each other.
MOVE TIMEOUT:
Dropping was stopped and disabled because one of the injection or
puncture motors had trouble moving. Dropping cannot restart until Ignis is power-
cycled. Land and inspect the injection and puncture motors. This message will only
appear on older versions of Ignis.
INJECTION A MOTION ERROR:
Dropping was stopped and disabled because the A-side
injection motor had trouble moving. Dropping cannot restart until Ignis is power-cycled.
Land and inspect the motor.
INJECTION B MOTION ERROR:
Dropping was stopped and disabled because the B-side
injection motor had trouble moving. Dropping cannot restart until Ignis is power-cycled.
Land and inspect the motor.
PUNCTURE MOTION ERROR:
Dropping was stopped and disabled because the punc- ture
motor had trouble moving. Dropping cannot restart until Ignis is power-cycled. This
error could lead to an in-flight fire if Ignis was not able to remove an injected sphere.
Use the camera and temperature sensor to monitor for an in-flight fire and use the
emergency release in that event. Land and inspect the motor.
UNKNOWN ERROR:
Dropping was stopped because of an error that the app did not
understand. Try to restart dropping. Check that you are using the latest version of the
app.
UNKNOWN HARD ERROR:
Dropping was stopped because of an error that the app did not
understand, and cannot be restarted until Ignis is power-cycled. Land and inspect Ignis.
Check that you are using the latest version of the app.
Last Updated
Page 121
Apr 13, 2022