Ignis Operations Manual
Drone Amplified
Figure 4.1.6b: Locking the needle assembly.
To lock the needle assembly in place, push inward on the black knob labeled “IGNIS” (as
shown in Figure 4.1.6b), and twist the knob clockwise until it stops, then pull back on the
knob to click it in place. Verify the needle assembly is locked by attempting to twist the
knob counter-clockwise. It should not be able to rotate.
4.1.7 Emergency Release Toggled
E-Release Toggled to Safe:
TOGGLED TO SAFE
For the M600, ensure that the emergency release dials (S1 and S2) shown in Figure 4.1.7
are rotated fully counterclockwise. Rotating both dials fully clockwise within 2 seconds of
each other will trigger the emergency release. For the Alta X and IF 1200 the emergency
release is triggered by holding down B and C, and no procedure is necessary to ready it. We
recommend periodically testing that the emergency release works properly while on the
ground, see
.
Last Updated
Page 33