Ignis Operations Manual
Drone Amplified
6.3 Stuck Ignition Sphere After Landing Checklist
6.3.1 Remove Needle Assemblies
Remove Needle Assemblies:
NEEDLES REMOVED
Remove the needle assemblies (
). This will ensure that no antifreeze can be
injected into the ignition sphere.
6.3.2 Trigger Dropper Emergency Ejection
Trigger Dropper Emergency Ejection:
TRIGGERED, EJECTED
On the M600 system, rotate both dials fully clockwise within 2 seconds of each other to
trigger the emergency release as shown in
. On the Alta X and IF 1200 press and
hold the B and C button to trigger the emergency release. Or, use the E-Release button in
the App to trigger an emergency release.
6.3.3 Battery Disconnect
Battery Disconnect:
DISCONNECTED
Unplug the power from Ignis.
6.3.4 Manually Remove Stuck Ignition Sphere
Manually Remove Stuck Ignition Sphere:
REMOVED
Manually remove the stuck ignition sphere. Proceed to the post-flight inspection
).
Last Updated
Page 51
Apr 13, 2022