CHARGER
INSTRUCTION MANUAL
C1 - XR AC/DC SMART BALANCE CHARGER
23
22
System Setting
OFF
/
OFF
ON
10%
-
100%
3.80V/C
-
4.10V/C
(
100
-
99900
mAh
)
OFF
/
ON
(
10
-
720
Min
)
System Setting
Item
Select
Description
When you start a charge process, the
internal safety timer automatically starts
running at the same time. It is
programmed to prevent overcharging.
If the battery proves to be faulty or if the
termination circuit cannot detect the full
battery. The value of the safety timer
should be generous enough to allow full
charging of the battery.
This sets the maximum charge
capacity that will be supplied to the
battery during charge. If the delta
peak voltage is not detected for any
reason or the safety timer has not
expired, this feature will
automatically stop the process at the
selected capacity value.
Key Beep sounds every time you
press a button. Buzzer beep or
melody sounds at various instances
during operation to alert certain
process events.
Adjust the LCD backlight
Set the cut-off voltage of LiPo, Lilon,
LiFe, LiHV, Pb batteries.
Press START for more than 2s for
factory reset.
21
System Setting
AUTO
/
OFF
(
50
-
200
mAh
)
Item
Select
Description
OFF
/ON
(
1
-
60
Min
)
(
1
-
10
Min
)
OFF
/ ON
(
30
C
/
86
F
-
80
C
/
176
F
)
Default
:
6-20mV
/
Cell
5
-
20mV
/
Cell
System Setting
The charger will operate with default values for the essential user settings
when it is powered on for the first time. The screen displays the following
system settings in sequence and the user can change the parameter value
on each screen.
When you want to change the parameter value, press START/ENTER to
make it blink, then change the value with INC or DEC. Then value will be
stored by pressing START/ENTER once.
Precharge Program
Attention: Please OFF this program
when under the normally charge
mode.
This is for cycle mode, set the wait
time between each charge or
discharge process.
This setting is for NiMH/NiCd battery
only. When the charger detects that
the delta peak value you set has been
reached, the charger will say the
battery is fully charged.
Trickle function is for full power
maintenance on battery packs after
fully charged.
The battery's internal chemical
reaction will cause the temperature
of the battery to rise. If the
temperature limit is reached, the
process will be terminated.
20
The charger will operate with default values for the essential user settings
when it is powered on for the first time. The screen displays the following
system settings in sequence and the user can change the parameter value on
each screen.
When you want to change the parameter value, press START/ENTER to make
it blink, then change the value with INC or DEC. Then value will be stored by
pressing START/ENTER once.