Tamarisk
®
320
Software ICD
35
Command Format:
Table 58 – Automatic Calibration Period Get Command Format
Byte
Value
Description
1
0x01
Start of message.
2
0x13
Automatic calibration period get command ID.
3
0x00
Parameters length.
4
checksum
Frame check sequence.
Response Format:
Table 59 – Automatic Calibration Period Get TXT Response Format
Byte
Value
Description
1
0x01
Start of message.
2
0x00
TXT Response
3
N
Parameters length.
4 to
(N+3)
Zero-terminated
text string
Message content example:
Example:
“
AUTOCAL: Interval= 300 sec.
”
Note trailing null is included in parameters length.
(N+4)
checksum
Frame check sequence.
Table 60 – Automatic Calibration Period Get ACK Response Format
Byte
Value
Description
1
0x01
Start of message.
2
0x02
ACK Response
3
0x02
Parameters length.
4, 5
0x0013
AutoCal Period Get Command ID.
6
checksum
Frame check sequence.
3.2.6 Automatic Calibration Activity Control – 0x26
Description
: This command shall control whether all automatic calibrations (autocal,
including range changes) are enabled or disabled. This command does not store calibration
activity mode in the NV Param. See section 3.5 for storing in NV Param.
NOTE