Tamarisk
®
320
Software ICD
46
Command Format:
Table 87 – AGC Level Bias Set Command Format
Byte
Value
Description
1
0x01
Start of message.
2
0x83
AGC Level Bias Set Command ID.
3
0x02
Parameters length.
4,5
unsigned integer
0 to 4095
AGC gain bias value.
0
= minimum level bias, level factor = -255
2047 (0x7FF)
= unity level bias, gain factor = 0
4095 (0x0FFF) = maximum level bias, gain factor = 255
6
checksum
Frame check sequence.
For level bias <= 2047, level _factor = 255*level_bias/2047-255
For level bias >= 2048, level factor = 255*(level_bias-2047)/2048
Figure 5– Level Bias Chart
Response Format:
Table 88 – AGC Level Bias Set Response Format
Byte
Value
Description
1
0x01
Start of message.
2
0x02
ACK Response
-256.000
-192.000
-128.000
-64.000
0.000
64.000
128.000
192.000
256.000
0
25
6
51
2
76
8
10
24
12
80
15
36
17
92
20
48
23
04
25
60
28
16
30
72
33
28
35
84
38
40
40
96
L
evel
B
ias
Level Bias Parameter