8. Final inspection
Toensuretheapplianceisworkingcorrectlyandsafely,checkthefollowingbeforeuse:
8.1 Gastightness
N.B.
All connections must be gastight.
!N.B.
The maximum pressure to which the gas control block may be exposed is 50 mbar.
➠
Test the connections for gastightness.
8.2 Gas pressure/pre-pressure
Theburnerpressureisfactoryadjusted;seetypeplate.Itisnotnecessarytotesttheburnerpressure.
Thepre-pressureindomesticinstallationsshouldbetestedhowever,asthiscanvary.
➠
Check the pre-pressure; see
Photo 16
for the measuring nipple on the gas control block;
➠
Contact the power company if the pre-pressure is not right.
8.3 Igniting the pilot and main burner
8.3.1 Pilot
➠
Test that the pilot ignites properly, see section 0 Remote control:
- the pilot burner should ignite at the fi rst attempt.
Ifthepilotdoesnotlight,then
➠
Check whether or not the ignition sparks:
a) If not, the ignition wire is probably touching something metal;
b) If it does, there is probably air in the pipes.
➠
Bleed off any air in the pipes and/or;
➠
Move the ignition wire so that it does not touch anything metal.
8.3.2 Main burners
Caution
The burners should ignite smoothly and should not pop as a result of postponed ignition.
➠
Check the function of the main burners from the standby (pilot fl ame) position:
- after opening the gas valve, the main burners should burn within a few seconds.
!Tip
When the gas valve is opened, the motor will run; this is audible.
1)Ifthemainburnersdoesnotburn:
➠
Check if button A on the gas control is in the position ON;
➠
Check if the space surrounding the pilot burner is free from objects;
➠
Check the placement of the wood/pebble set.
➠
If necessary, correct the above mentioned faults.
➠
Test the main burner 5x for a good operation.
2)Ifmainburnersignites,butgooutagainafterapprox.22seconds,please:
➠
Check the wiring of thermocouple 2 for:
- Loosewiring;
- Wronglyconnectedwiring;
- Short-circuit;
- Brokenwire.
➠
Check if thermocouple 2 is dirty.
➠
Check if thermocouple 2 is positioned correctly in the fl ame;
see fi g. 10.
➠
Check if thermocouple 2 is defective; see chapter 11, table 4
under J7.
➠
Check if the receiver is defective; see chapter 11, table 4
under J8.
➠
If necessary, correct the above mentioned faults.
➠
Test the main burner 5x for a good operation.
B
B
C
SECTION B-B
25
15
38C-1894 /0
Fig 10