English
INS T ALLAT I ON M A N U A L
!Tip
The opening in the chimney breast may be made horizontal and vertical.
Ø
Place the inner frame (A); unscrew bolts (D and F) for this.
!Caution
The inner frame should be placed in the correct way. Two positions are possible. Placing the inner frame with a
rotation of 180° is not allowed (see Appendix 3, fig. 4).
!Tip
•
When the chimney breast is made of bricks, the inner frame can be built with bricks at the same time.
•
In case of a different material, the inner frame can be glued or fastened with four countersunk screws.
Ø
Remove the bracket with the gas control (B) from the appliance and place these self-tapping screws back in the
appliance.
Ø
Attach the bracket with gas control to the inner frame (A). Proceed as follows:
•
Unwind the cables. This will, amongst other things, prevent a poor operation of the ignition.
•
Unwind the flexible gas pipe(s).
•
Mount the bracket with the gas control to the inner frame (A). The slotted hole falls in allen screw (C); the hole
at the bottom falls over the head of allen screw (D).
•
Fix the bracket with allen screw (C).
!Caution
•
Avoid kinks in the pipes.
•
Do not lay the cables of the ionisation and ignition pins along metal parts, wiring and other components.
Ø
Connect the gas pipe with gas tap (see section 5.2).
Ø
Bleed the gas pipe.
!Tip
If the gas tap is closed, the bracket with gas control can be easily removed by loosening the clamp coupling under
the gas control and loosening the allen screw (C) by a few turns. The bracket with the gas control can now be lifted
and removed towards the front out of the control hatch.
Ø
Connect the 230V mains voltage with protective earth using the correct type of plug. The other side of the power
cable can be easily connected to the universal 230V plug in the control hatch. Use this universal 230V plug to
disconnect the appliance from the power supply, if necessary.
!Caution
If the 230V power cable is damaged, replace it by a similar power cable or a power cable that is available from your
dealer.
Ø
Place the data plate in its intended clamp (G).
Ø
Mount the outer frame with door (E) to the inner frame using two allen screws (D and F).
!Tip
The outer frame can be placed in such a way that the door turns to the left or right.
!Caution
Always close the control hatch with the lock (H) because of the electricity behind the door (230V).
You can operate the lock with a fitting flat object.
5.8 Concentric system
5.8.1 General
The appliance is connected to a flue gas discharge / combustion air supply system delivered by DRU, hereafter
referred to as the concentric system. The diameter for this connection is indicated in appendix 2, table 2. The
passage to the outside can be created with a wall terminal (C11) or a roof terminal (C31). If necessary, an existing
chimney can be used (see section 5.8.4).
!Caution
•
Only use the concentric system supplied by DRU. This system has been tested in combination with the
appliance. DRU cannot guarantee a proper and safe operation of other systems and does not accept any
responsibility or liability for this.
•
Use a chimney set for the connection to the chimney, DRU will be able to supply it.
•
DRU's concentric system is intended for indoor use and may therefore not be used outdoors, with the
exception of the sections intended for that purpose such as roof and wall terminals.
9
Summary of Contents for Metro 200XT
Page 29: ...E n g l i s h INSTALLATION MANUAL 29 C G F D A E H B 38C 1747 b 0 38C 1868 d 0 4 3...
Page 31: ...E n g l i s h INSTALLATION MANUAL 31 X 3 1 T U 2 38C 2148 0 38C 2149 0 7b 7a...
Page 32: ...E n g l i s h INSTALLATION MANUAL 32 38C 2295 0 D C 8...
Page 34: ...E n g l i s h INSTALLATION MANUAL 34 38p 0627 2 A F G H E D K L J I B C 2x 2x 17...
Page 36: ...E n g l i s h INSTALLATION MANUAL 36 38p 0630 1 B C 38p 0631 0 E D 21 20...
Page 37: ...E n g l i s h INSTALLATION MANUAL 37 38p 0632 1 F G 22...
Page 38: ...E n g l i s h INSTALLATION MANUAL 38 38p 0633 1 G H 38p 0634 1 I J 24 23...
Page 39: ...E n g l i s h INSTALLATION MANUAL 39 38p 0635 1 K 38p 0636 1 L C 26 25...
Page 40: ...E n g l i s h INSTALLATION MANUAL UK 38p 0637 1 II I III I II III 27...