14
English
s a x o
s l
80 -
i n s t r u c t i o n
f o r
i n s ta l l at i o n
6.8.3 Primary aeration of the burners
Caution
Adjusting the primary aeration only applies to appliances used in Belgium.
Whenthetraysurroundingtheburnersisremoved,youcanseethethrottlerings(PaandPb)thataremountedon
thepipesthatarefixedtotheburners(burnerpipes);see
fi g. 11
.
Theprimaryaerationoftheburnerscanbeadjustedbyrotatingthethrottlerings.
Caution
Rotate the throttle ring at the front left (Pb) with its opening towards the pilot fl ame burner. This throttle ring has only
1 hole with a diameter of 7 mm and 1 with a diameter of 13 mm (see
fi g. 11
).
Thestepstobetakenaredescribedbelow:
➠
Take the tray surrounding the burners (M) out of the appliance; see
fi g. 10a
.
➠
Unscrew the socket cap screw (O) of a throttle ring (P), see
fi g. 11
.
➠
Rotate the throttle ring (P) when using gas G25 in such a way, that the holes with the 7 mm diameter are directly
opposite the 15 mm holes in the burner pipe; see
fi g. 11
.
➠
Screw the socket cap screw (O) into the threaded hole above the 7 mm diameter hole.
➠
Repeat this procedure for the other 3 burner pipes.
➠
Return the tray surrounding the burners (M).
Afb. 11
Afb. 10b
UK
Summary of Contents for Saxo SL 80
Page 17: ...17 E n g l i s h saxo sl 80 instruction for installation Afb 16c Afb 16d Afb 16e Afb 16f UK...
Page 18: ...18 E n g l i s h saxo sl 80 instruction for installation Afb 16i Afb 16j Afb 16g Afb 16h UK...
Page 27: ...27 saxo sl 80 Notes...
Page 28: ...DRU Verwarming B V The Netherlands Postbus 1021 NL 6920 BA Duiven Ratio 8 NL 6921 RW Duiven...