Copyright 2022 Baker Hughes Company.
English–UNIK 5*00 Series | 7
Note:
Fluid classification complies with European Regulation (EC) No 1272/2008 and GB CLP
Regulation, UK S.I. 2019/720. Statements comply with European Pressure Equipment Directive
2014/68/EU and UK S.I. 2016/1105; amended by S.I. 2019/696. Refer to document K0581 for
product classification and regulatory information.
3.3.2 Pressure Containment
The pressure containment of the sensors is shown in Table
5700
Fluids compatible with titanium grades 2, 4 and 5.
Notes:
For pressure connector option PW: immersion
fluid must be compatible with Kynar.
For electrical connector options N and P:
immersion fluid must be compatible with Kynar.
For electrical connector options U and V:
immersion fluid must be compatible with TPE
-
U.
For electrical connector options P and V:
immersion fluid must be compatible with nitrile
butadiene rubber.
5800/5900
0
–
200
bar (0
–
2900
psi)
Fluids compatible with stainless steel 316L and
Hastelloy C276.
201
–
500
bar (2915
–
7250
psi)
Liquids and group II gases compatible with
stainless steel 316L.
501
–
700
bar (7265
–
10150
psi)
Group II liquids and group II gases compatible
with stainless steel 316L.
Table
2: Pressure Containment
Product
Pressure Range
Pressure Containment
5000/5600/5700
0
–
150
mbar (2
psi)
10 × FS
0
–
70
bar (1000
psi) gauge
6 × FS (200
bar (2900
psi) maximum)
0
–
70
bar (1000
psi) absolute
200
bar (2900
psi) maximum
>70
bar (1000
psi)
1200
bar (17400
psi) except for pressure
connector options PX, RA and RF which are
limited to 600
bar (8700
psi)
Note:
Differential (–ve port) must not exceed
positive port by more than 6 × FS (15
bar
(200
psi) maximum).
5800/5900
0
–
50
bar (725
psi) gauge
6 × FS (200
bar (2900
psi) maximum)
0
–
50
bar (725
psi) absolute
200
bar (2900
psi) maximum
>50
bar (725
psi)
1200
bar (17400
psi) maximum
Table
1: Media Compatibility (Continued)
Product
Pressure Range