background image

Visit our website at: http://www.harborfreight.com

 Email our technical support at: productsupport@harborfreight.com

Owner’s Manual & Safety Instructions

Save This Manual

 

Keep this manual for the safety warnings and precautions, assembly, 

operating, inspection, maintenance and cleaning procedures.  Write the product’s serial number in the 
back of the manual near the assembly diagram (or month and year of purchase if product has no number). 
Keep this manual and the receipt in a safe and dry place for future reference. 

17d

When unpacking, make sure that the product is intact 

and undamaged.  If any parts are missing or broken, 

please call 1-888-866-5797 as soon as possible.

Copyright

©

 2017 by Harbor Freight Tools

®

.  All rights reserved.  

No portion of this manual or any artwork contained herein may be reproduced in 

any shape or form without the express written consent of Harbor Freight Tools.  

Diagrams within this manual may not be drawn proportionally.  Due to continuing 

improvements, actual product may differ slightly from the product described herein.  

Tools required for assembly and service may not be included.

Read this material before using this product. 
Failure to do so can result in serious injury. 
SAVE THIS MANUAL.

Summary of Contents for submersible

Page 1: ...ence 17d When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2017 by Harbor Freight Tools All...

Page 2: ...d at all costs 6 The Pump must be protected from frost 7 The Pump must be protected from running dry 8 Access by children should also be prevented with appropriate measures 9 To prevent death from ele...

Page 3: ...rt as required check the Pump regularly with start up tests Power Supply 1 The Pump is equipped with a shock proof plug according to regulations The Pump is designed to be connected to a 120VAC 60Hz G...

Page 4: ...art the Pump Operation After reading these instructions consider the following points before starting the Pump 1 Verify that the Pump rests on the floor of the basin if it is not suspended by the hand...

Page 5: ...ne voltage 4 Check valve sold separately stuck or installed backwards 1 Clean out dirt and debris from impeller 2 There must be at least 2 1 4 deep water for the Pump to operate properly 3 Consult an...

Page 6: ...1 Power Cable 1 3 Self Tapping Screw 5 4 Main Body Subassembly 1 5 Screw 4 6 O Ring 2 7 Base Cover 1 8 Cable Sheath 1 9 Cable Guide 1 10 Cable Fastener 2 11 Capacitor 35Uf 1 12 Cable Connector 1 13 S...

Page 7: ...Page 7 For technical questions please call 1 888 866 5797 Item 63477 Assembly Diagram...

Page 8: ...o the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take a...