Safety Concerns
2-1
2. Safety Concerns
General Safety Guidelines
•
Make certain that the operator reads and understands all the information in this manual.
•
All unauthorized individuals must be kept away from the equipment when in operation.
•
All guards must be in place when the equipment is in operation.
•
Exercise caution when moving the unit (See Appendix – Product Dimensions for full details).
•
Maintain instruction and safety decals. Replace damaged decals as necessary (see safety
decals in Figure 2-1 below).
Heating Appliance
*CAUTION! This unit is a heating appliance.*
Hot Heat Transfer Fluid (HTF) is supplied to the unit via circulation lines and the heat is
distributed by the fan motor.
HTF
*CAUTION! At no time should automobile antifreeze be used in your DRYAIR system. The use of
automobile antifreeze will void your DRYAIR warranty. Always use Propylene Glycol as the
HTF.*
•
DRYAIR pre-mixed HTF is made up of 50% “Dowfrost ® HTF” or “Boss Chill PG” and
50% water by weight, to provide freeze protection down to -28°F (-33°C).
•
The
Glycol/Water Mixture Chart
(Table 1) will provide more information on the proper
mixture for your area.
Figure 2-1: Safety Decals