33
Appendix B
One of the reasons Drytac has earned a reputation for unmatched customer service is that we
value our
customers‟ opinions. The
Jet
Mounter
™
has evolved in response to such input from
the field. Our B Revision
Jet
Mounters, for example, have push button control panels with a
redesigned user interface. The following chart is provided as a quick-reference guide.
B Revision Functions
ACTION
PROGRAMMED SOFTWARE FUNCTIONS
AUTO MODE
Operation
Alarm
Photocell LED
Power Up or E-Stops Reset
Will not Run
Needs Reset
No
Yellow
FWD button pressed
Normal operation at
set speed
No
Green
Photocell interrupted
Machine stops
Yes
Flash Red
Photocell cleared
Ready to start
No
Green
E-Stops Activated
Will not Run
No
Flash Yellow
Press and Hold Rev. Button JM63/JM44-54
Jog speed Rev./
Will not run
Yes
REV Green
FOOT MODE
FOOT pedal pressed, FWD mode
Set speed, FWD
No
Green
Photocell interrupted. FP still depressed
Jog mode
Yes
Flash Red
Photocell cleared. FP still depressed.
Jog mode
No
Green
Photocell cleared. FP dep. Switch to Auto
FWD at set speed
No
Green
FOOT pedal released
Machine stops
No
Green
Restart by FP, no buttons pressed
Set speed FWD
No
Green
Press and hold REV in Foot Mode,
Jog mode REV
Yes
REV Green
Release REV button while depress FP
Jog mode REV
Yes
REV Green
In Rev. with Foot on pedal- press AUTO
Machine Stops,
Ready to start
No
Green
Table Down, FOOT pedal released. (JM63 only)
Will not Run
No
Flash Green
Table Down, FOOT pedal pressed. (JM63 only)
Jog mode
Yes
Flash Green