    15.  Do not burn garage, gasoline or any other flammable liquids in this boiler.

    16.  This is a wood and anthracite coal burning boiler and should not be altered in any way.

    17.  Do not burn boiler over 200 degrees water temperature or warranty will be void! 

    18.  When used in a large greenhouse and they are forecasting a cold night it is advisable to load and fire

your boiler at 3 to 4 o’clock in the afternoon so that you do not fall behind. If you wait till the sun sets to fire your

boiler you may be playing catch up all night. In the morning when it is cold with a sunny day in the forecast you

may want to consider shutting the boiler down at 5 o'clock in the morning so that when the sun comes out and

it warms up so that there's not to much heat in your green house till the boiler fire dies down.

Note: When burning coal, shake ashes every 12 hours if possible. You must keep your ashes cleaned out from

under grating. This may require emptying your ash pan daily. If there is no air space under the grates, the

grates will warp and become inoperable.

Starting A Coal Fire

Fully open Samson Draft Regulator. Place crumpled paper and kindling wood on grate and ignite with match or

lighter. Use a good amount of kindling to get the fire started. Add larger pieces of wood to get a hot fire. Once

you have a hot fire, add 2” of coal over the entire grate area. As the coal starts burning and glowing red add an-

other 2” layer of coal. Keep adding coal until you have an 8” body of fire, but don’t add too much at a time or

you could smolder the fire. You can now add up to 50 lbs. of coal at a time, adjust draft on Samson Draft Regu-

lator to meet your desired water temperature. NOTE: You can also use charcoal briquettes for a fire starter.

With new steel there is a small amount of oil or dirt on the metal. You may smell an odor. This is normal during

the first operation. You may want to assemble the boiler out of doors and build a small fire in it to “BURN OFF”

this dirt and oil before installing unit.

Starting A Wood Fire

Fully open Samson Draft Regulator. Place crumpled paper and kindling wood on grate and ignite with match or

lighter. Use a good amount of kindling to get the fire started. Add larger pieces of wood to get a hot fire. Once

you have a hot fire add wood as needed, adjust draft on Samson Draft Regulator to meet your desired water

temperature. Allow ash to build up on top of grates, this will not choke fire until it covers louvers. For most effi-

cient burning keep approximately 2” to 3” of ash on grates at all times.

With new steel there is a small amount of oil or dirt on the metal. You may smell an odor. This is normal during

the first operation. You may want to assemble the boiler out of doors and build a small fire in it to “BURN OFF”

this dirt and oil before installing unit.

Creosote – Formation and Need for Removal

When wood is burned slowly, it can produce tar or other organic vapors, which combined with expelled mois-

ture will form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow burning fire.

As a result, creosote residue accumulates on the flue lining. When ignited, this creosote

makes an extremely hot fire. The chimney connector and chimney should be inspected at least twice monthly

during the heating season to determine if a creosote build-up has occurred. If creosote has accumulated, it

should be removed to reduce the risk of a chimney fire.

NOTE:

Firewood must be seasoned for one year. That means cut, split and stacked under shelter with sides

open so the wind can dry it. Wood needs to have no more than 20% moisture. Stack indoors 1 day prior to

burning.

3

Power Boiler Manual 2017.qxp_Layout 1  2/13/17  9:32 AM  Page 3

Summary of Contents for DS5000

Page 1: ...nstructions carefully Install smoke and carbon monoxide detectors MADE IN USA By D S MACHINE SHOP Do Not Discard This Manual DS Power Boilers High Efficiency Boilers Models DS5000 DS6000 DS7000 OWNER S MANUAL Power Boiler Manual 2017 qxp_Layout 1 2 13 17 9 32 AM Page 1 ...

Page 2: ...be very hot 18 Make sure your single wall chimney connectors have at least 3 screws per joint 19 When starting a fire circulating pump must be running continuously 20 If circulating pump is installed you must install a high limit aquastat set at 190 degrees Fahrenheit 21 Always install a mixing valve when installing a domestic coil Operational Work Practice Standards 1 When burning wood burn only ...

Page 3: ...steel there is a small amount of oil or dirt on the metal You may smell an odor This is normal during the first operation You may want to assemble the boiler out of doors and build a small fire in it to BURN OFF this dirt and oil before installing unit Starting A Wood Fire Fully open Samson Draft Regulator Place crumpled paper and kindling wood on grate and ignite with match or lighter Use a good ...

Page 4: ...ssure Gauge 3 Damper 4 30 Safety Valve 5 3 4 Boiler Coil 6 4 or 5 Gallon Coil 7 Aquastat All D S Boilers must be plumbed by a Qualified Licensed Plumber or D S is not responsible for warranty Failure to follow installation and basic operation will void the warranty All Boilers are tested to 100psi Recommended working pressure 12psi NOTE This Boiler set up is only a D S Machine Design Each set up c...

Page 5: ...the water Valve Hot Water Aquapure Filter System Hot Water Heater 40 Gal Hot Rock Tank 70 145 Mixing Valve Cold Water Dip Tube Water Fire Door Ash Door 6 High Ash Pan Drain Valve W A T E R W A T E R W A T E R W A T E R Valve Hot Water Aquapure Filter System Mixing Valve Cold Water Dip Tube Water Fire Door Ash Door 6 High Ash Pan Circulator Pump Drain Safety Valve DS 4GPM FC DS 5GPM FC Domestic Coi...

Page 6: ...ar ried back into the heater The connector pipe should be installed so that the upper pipe section fits inside the lower section This way any condensation building up inside the pipe will stay inside the pipe as it flows down the inside surface Horizontal pipe runs should have the pipe seams turned up Particular attention should be paid to the point where the flue passes through a wall or ceiling ...

Page 7: ...06 water column It is required to abide by the manufacturer s instructions on Class A chimneys as well as local building codes It is not recommended to build a chimney on an addition that is lower than the main part of your building Do Not extend the stovepipe past the inside of a masonry chimney liner Never connect this unit to a chimney serving another appliance Should you have a problem with in...

Page 8: ...d to maintain the boiler pressure at 12 15 lbs Every degree the temperature rises the boiler will gain 1 lb of pressure The expansion tank will absorb the pressure and keep it at 12 15 lbs in normal temperature ranges This normally gets hooked up to the hot water horizontal line close to the boiler 6 Circulator Pump A Circulator Pump is designed to circulate water through your heating system This ...

Page 9: ...Forced Draft Kit Setup Remove the rear draft intake plate Replace with draft fan Use bolts to cover holes 9 Power Boiler Manual 2017 qxp_Layout 1 2 13 17 9 32 AM Page 9 ...

Page 10: ...iler Models DS5000 DS6000 DS7000 DS5000 20 14x3 4 screws DS6000 22 14x3 4 screws DS7000 24 14x3 4 screws Install side and back panels first Back panel goes inside of side panels Top panel goes outside of all panels Power Boiler Manual 2017 qxp_Layout 1 2 13 17 9 32 AM Page 10 ...

Page 11: ... damper before installing At least a 0 06 water column on all D S Coal Boilers Manuel dampers work good but you need to be cautious because a manuel damper can restrict draft so much that it can create carbon monoxide Problem 3 Poor Draft Solution Check and clean chimney and single wall chimney connectors Check chimney draft there should be at least a 0 06 inch of water column This service is prov...

Page 12: ...wner is responsible for labor and costs to complete the repair The owner may at his op tion and with D S Stoves approval have the stove shipped to the factory for repair All labor and material costs for repair at the factory will be borne by D S Stoves The owner is responsible for all shipping costs D S Stoves gaskets paint or enameled parts firebrick and furnace cement are not covered by this Lim...

Reviews: