background image

Features

10

Features

Telephones

Telephone Connections

The Classic PC1565 is a powerful
communications device and it is
important that you make the correct
connections to the telephone line.
The line may be connected in differ-
ent ways for different applications.

Connecting the Phone Line

NOTE: The control panel should
always be the first device on the line.
This is to ensure various features work
correctly such as line seizure.

Telephone Connections

23

Clearing Troubles

[1]

Further Sub-Menu of
Troubles

If [1] comes ON, push [1] again for
specific trouble present. LED lit
after pushing [1] again will indicate
type of trouble.

[1]

Low Battery

Check Battery. May be ON if battery
is below 11.5 volts.

[2]

Bell Circuit Trouble

Panel senses open condition on bell
circuit.

[3]

General System Troubles

Only generated if PC5204 or
PC5400 have fault conditions.

[4]

General System Tamper

Tamper on module. [*][6][Master
Code][*] to view which module is in
tamper via the event buffer.

[5]

General Supervisory
Trouble

Loss of communication with
module. [*][6][Master Code][*] to
view event buffer for details. Also try
[*][8][Engineer Code][902].

Clearing Troubles

Summary of Contents for Classic PC1565

Page 1: ...Unit C51 Winfrith Technology Centre Winfrith Newburgh Dorchester DT2 8DH Telephone 01305 851700 Fax 01305 851660 Email Sales dscuk co uk Web Site www dscuk co uk Unit 21 Hull Business Centre Guildhall...

Page 2: ...ation 29 The Language Barrier 29 Using the Big Books 30 Using the Big Books The summary of programme options is also a good troubleshooting tool For example if you are having diffi culty getting the p...

Page 3: ...1482 322228 329911 Features 32 Using the Big Books are the options that you need to programme in order to have the features work appropriately Now look at page 27 This is the beginning of the Programm...

Page 4: ...external sounders in the areas described on the specification 4 Connect the mains cable to the unswitched fuse spur and to the control panel DO NOT POWER UP YET InstallingtheClassicPC1565ControlPanel...

Page 5: ...nications if pro grammed InstallingtheClassicPC1565ControlPanel Features 30 Features UsingtheBigBooks How to use the Installation Manual included with this panel The Installation Manual that accom pan...

Page 6: ...it 1 02 Delay 2 Final Exit 2 03 Instant Normal Zone 05 Interior Stay Away Part Set Zone will be omitted if no Final exit zone is activated Zone arms if final exit activated 06 Delay Stay Away zone Alw...

Page 7: ...565 using double end of line resistors DEOL Always follow the manufacturer s instructions when installing such devices Panic Button Door Contact surface Break Glass Detector Door Contact flush 5K6 Res...

Page 8: ...ion and set the time and date Wiring PIRs 27 Basic Programming Be sure to record your new Master Code on the System Information page in this booklet NOTE We recommend that the factory default or obvio...

Page 9: ...dash indicating the option is now OFF Go through each of the options in the section and determine if the option should be ON or OFF Once all the options are selected correctly press the key The keypa...

Page 10: ...ault setting of single end of line resistors to our recommended double end of line resistors Open the Installation Manual to page 29 30 and find section 013 First System Option Code section 013 is a t...

Page 11: ...l entries in section 005 require 3 digits To get into engineering programming mode you must press 8 followed by your engineering code At default this will be 5555 At this point the keypad will display...

Page 12: ...Clearing Troubles 1 Further Sub Menu of Troubles If 1 comes ON push 1 again for specific trouble present LED lit after pushing 1 again will indicate type of trouble 1 Low Battery Check Battery May be...

Page 13: ...ry out the following check the connections on all Keybus connected devices check the cable run distance check that cable type is 22 Clearing Troubles 4 Failure to Communicate Panel unable to send info...

Page 14: ...Features Clearing Troubles If the orange Trouble LED is lit there is trouble on the system To view press 2 The trouble condition will be dis played on the LCD keypad Scroll through the display using...

Page 15: ...Commands 8 Access to Engineering Functions Press 8 Engineer Code to enter engineering functions Installation Manual page 12 9 Arming without Entry Delay Press 9 Access Code the panel will remove the e...

Page 16: ...pad will flash the program light and turn on the zone light for any codes already programmed Enter the two digit user number for the code you want to program The corresponding zone light will flash En...

Page 17: ...by using commands These com mands are very similar on all DSC products 1 Zone Bypass Features Enter 1 Bypass light flash Enter two digit zone number to bypass Zone light ON push key 2 Display Trouble...

Page 18: ...Features 16 Features Classic PC1565 Expansion Flowchart Classic PC1565 Expansion Flowchart 17 Features...