6
2.2 Keybus Wiring
The VPM5580TC module has 4 terminals marked
Keybus (red, black, yellow and green). Connect
these four terminals to the 4 terminals on the main
control panel marked Keybus (red, black, yellow
and green).
Keybus Connection
If the Keybus is not wired correctly the
VPM5580TC will not operate properly.
2.3 Confirming Supervision of the
VPM5580TC Module
The VPM5580TC will function properly as soon as all
wiring is complete and power is applied. However,
to confirm that the security control panel is
supervising the VPM5580TC, you should follow
these steps:
1. Wire the VPM5580TC module to the Keybus.
2. The panel will automatically search for all
modules on the system. The search takes
approximately 1 minute. From this point on, if
any modules are removed from the system, a
Supervisory Trouble will be generated.
3. To confirm supervision, enter Installer’s
Programming ([*][8][Installer’s Code]), and
then enter section [903]. On LED keypads,
light 24 ON represents successful VPM5580TC
supervision. On LCD keypads, the description
“Escort5580” will be displayed if successful.
4. If this is not successful, check all wiring to the
VPM5580TC.
2.4 Connecting the PL-513 or
PSC04 Controller
The RJ-11X telephone jack on the VPM5580TC is for
connecting the PL-513 or PSC04 Controller. Use an
RJ-11X connector cable to connect the VPM5580TC
to the PL-513 or PSC04. Plug the PL-513 or PSC04
Controller module into any unswitched AC outlet.
Connect Automation items for lighting, outlet and
temperature control. These items plug into AC outlets
located throughout the installation.
The PL-513 or PSC04 Controller receives commands
from the VPM5580TC module and sends out signals
to control the various Automation items connected.
The following diagram shows the cable currently
required for connecting the VPM5580TC to the PL-
513 or PSC04. With the jacks side by side (tabs
facing up), the colours of the wire in each jack will
appear in the same order from left to right. This
cable is called a “Straight Through Cable” as per
telephone industry standards.
Do not use a “Swapped”, “Flipped” or
“Crossover” cable as it will not work
with the VPM5580TC. To verify whether
you have the correct type of cable, plug
in the PSC04 (PL513). The red LED
should turn ON. Connect the telephone
cable to both the PSC04 (PL513) and the
VPM5580TC. If the LED on the PSC04
(PL513) turns OFF and remains unlit,
you are using the wrong type of cable.
G E T T I N G S T A R T E D
51
Appendix B
A U T O M A T I O N I T E M H O U S E C O D E S & U N I T N U M B E R S
Enter
Code
[000]
A 1
[001]
A 2
[002]
A 3
[003]
A 4
[004]
A 5
[005]
A 6
[006]
A 7
[007]
A 8
[008]
A 9
[009]
A 10
[010]
A 11
[011]
A 12
[012]
A 13
[013]
A 14
[014]
A 15
[015]
A 16
[016]
B 1
[017]
B 2
[018]
B 3
[019]
B 4
[020]
B 5
[021]
B 6
[022]
B 7
[023]
B 8
[024]
B 9
[025]
B 10
[026]
B 11
[027]
B 12
[028]
B 13
[029]
B 14
[030]
B 15
[031]
B 16
[032]
C 1
[033]
C 2
[034]
C 3
[035]
C 4
[036]
C 5
[037]
C 6
[038]
C 7
[039]
C 8
[040]
C 9
[041]
C 10
[042]
C 11
[043]
C 12
[044]
C 13
[045]
C 14
[046]
C 15
[047]
C 16
[048]
D 1
[049]
D 2
[050]
D 3
[051]
D 4
Enter
Code
[205]
M 14
[206]
M 15
[207]
M 16
[208]
N 1
[209]
N 2
[210]
N 3
[211]
N 4
[212]
N 5
[213]
N 6
[214]
N 7
[215]
N 8
[216]
N 9
[217]
N 10
[218]
N 11
[219]
N 12
[220]
N 13
[221]
N 14
[222]
N 15
[223]
N 16
[224]
O 1
[225]
O 2
[226]
O 3
[227]
O 4
[228]
O 5
[229]
O 6
[230]
O 7
[231]
O 8
[232]
O 9
[233]
O 10
[234]
O 11
[235]
O 12
[236]
O 13
[237]
O 14
[238]
O 15
[239]
O 16
[240]
P 1
[241]
P 2
[242]
P 3
[243]
P 4
[244]
P 5
[245]
P 6
[246]
P 7
[247]
P 8
[248]
P 9
[249]
P 10
[250]
P 11
[251]
P 12
[252]
P 13
[253]
P 14
[254]
P 15
[255]
P 16
Enter
Code
[052]
D 5
[053]
D 6
[054]
D 7
[055]
D 8
[056]
D 9
[057]
D 10
[058]
D 11
[059]
D 12
[060]
D 13
[061]
D 14
[062]
D 15
[063]
D 16
[064]
E 1
[065]
E 2
[066]
E 3
[067]
E 4
[068]
E 5
[069]
E 6
[070]
E 7
[071]
E 8
[072]
E 9
[073]
E 10
[074]
E 11
[075]
E 12
[076]
E 13
[077]
E 14
[078]
E 15
[079]
E 16
[080]
F 1
[081]
F 2
[082]
F 3
[083]
F 4
[084]
F 5
[085]
F 6
[086]
F 7
[087]
F 8
[088]
F 9
[089]
F 10
[090]
F 11
[091]
F 12
[092]
F 13
[093]
F 14
[094]
F 15
[095]
F 16
[096]
G 1
[097]
G 2
[098]
G 3
[099]
G 4
[100]
G 5
[101]
G 6
[102]
G 7
Enter
Code
[103]
G 8
[104]
G 9
[105]
G 10
[106]
G 11
[107]
G 12
[108]
G 13
[109]
G 14
[110]
G 15
[111]
G 16
[112]
H 1
[113]
H 2
[114]
H 3
[115]
H 4
[116]
H 5
[117]
H 6
[118]
H 7
[119]
H 8
[120]
H 9
[121]
H 10
[122]
H 11
[123]
H 12
[124]
H 13
[125]
H 14
[126]
H 15
[127]
H 16
[128]
I 1
[129]
I 2
[130]
I 3
[131]
I 4
[132]
I 5
[133]
I 6
[134]
I 7
[135]
I 8
[136]
I 9
[137]
I 10
[138]
I 11
[139]
I 12
[140]
I 13
[141]
I 14
[142]
I 15
[143]
I 16
[144]
J 1
[145]
J 2
[146]
J 3
[147]
J 4
[148]
J 5
[149]
J 6
[150]
J 7
[151]
J 8
[152]
J 9
[153]
J 10
Enter
Code
[154]
J 11
[155]
J 12
[156]
J 13
[157]
J 14
[158]
J 15
[159]
J 16
[160]
K 1
[161]
K 2
[162]
K 3
[163]
K 4
[164]
K 5
[165]
K 6
[166]
K 7
[167]
K 8
[168]
K 9
[169]
K 10
[170]
K 11
[171]
K 12
[172]
K 13
[173]
K 14
[174]
K 15
[175]
K 16
[176]
L 1
[177]
L 2
[178]
L 3
[179]
L 4
[180]
L 5
[181]
L 6
[182]
L 7
[183]
L 8
[184]
L 9
[185]
L 10
[186]
L 11
[187]
L 12
[188]
L 13
[189]
L 14
[190]
L 15
[191]
L 16
[192]
M 1
[193]
M 2
[194]
M 3
[195]
M 4
[196]
M 5
[197]
M 6
[198]
M 7
[199]
M 8
[200]
M 9
[201]
M 10
[202]
M 11
[203]
M 12
[204]
M 13
firealarmresources.com