Installation Instructions

LC-100PI

PIR Motion Detector with Pet Immunity up to 25kg

The LC-100PI detector uses a special designed optical Lens with unique Quad  (Four element) PIR Sensor and
new ASIC based electronics optimized to eliminate false alarms, caused by small animals and Pets. The LC-
100PI provides unprecedented levels of immunity against visible light. The Detector offers an exceptional level
of detection capability and stability for every security installation. The LC-100PI is supplied with Wide Angle
lens.

The LC-100PI provides Pet immunity up to 25Kg (55 lbs). For better immunity avoid installation in areas where pets
can reach upwards.

TYPICAL INSTALLATION

Select mounting location

Choose a location most likely to intercept an intruder. See detection pattern(Fig.5). The Quad high quality sensor detects motion crossing
the beam; it is less sensitive detecting motion towards the detector. The LC-100PI performs best when provided with a constant and
stable environment.

Avoid the following locations

*  Facing  direct  sunlight.  *  Facing  areas subject  to  rapid  temperature  changes.  *  Areas with  air  ducts  or  substantial  air  flows.

MOUNTING THE DETECTOR

1. 

To   remo ve  th e   fron t  co ver  (Fi g .4),   un screw   th e  h ol d in g  scre w  (Fi g .4-11 )  an d   g e nt ly  ra ise   the   fro nt   cove r.

2.

To  remove   th e  PC  b oa rd,  carefu ll y  u nscrew   th e  h ol di ng   screw   (Fi g.4 -9)  l oca ted   o n  t he   PC  bo ard  (Fig .4-1 0).

3.

Break out the desired holes (Fig.2-B or C) for proper installation (flat or corner).

4.

The circular and rectangular indentations at the bottom base are the knockout holes (Fig.2-D) for wire entry. You may also use mounting
holes that are not in use for running the wiring into the detector.(For option with bracket (Fig.1 & 3)(Fig.4-7), lead wire through the 
bracket)

5.

Mount the detector base to the wall, corner or ceiling. (For options with bracket install bracket).

6.

Reinstall the PC board by fully tightening the holding screw. Connect wire to terminal block.

7.

R ep l ace   th e  cove r  b y  in se rti ng   i t  ba ck  in   t he   a p pro p ri at e  clo si ng   pi n s  a nd   scre w   i n   th e   h ol d in g   scre w.

DETECTOR INSTALLATION

Terminal block connections 

(Fig.6)

Terminals 1 & 2 - Marked T2 and T1 (TAMPER)

 If a Tamper function is required connect these terminals to a 24-hour normally closed

protective zone in the control unit. If the front cover of the detector is opened, an immediate alarm signal will be sent to the control unit.

Terminals 3 & 4 - Marked NC and C (RELAY 

) These are the output relay contacts of the detector. Connect to a normally closed zone in

the control panel.

Terminal 5 - Marked 

 EOL 

 End of line option.

Terminal 6 - Marked 

 - 

 (GND) 

Connect to the negative Voltage output or ground of the control panel.

Terminal 7 -  Marked 

 + 

 (+12V) 

Connect to  a  positive Voltage output of 8.2 -16Vdc source (usually from the  alarm  control unit).

D

C

C

B

B

B

C

C

C

B

A

A

FIG  2  

- Knockout h oles

FIG 4  

- Dete ctor In stallation

1

3

4

5

6

7

8

9

10

11

FIG  1 - 

Bracket Installa tion

1

3

15m

FIG 5 

- Lens pattern

Wall Mo unt
Br acket

Ceiling Mount
Bra cket

FIG  3 

- Bracke t options

1

2

FIG 6 

- Terminal block

D

1

2

3

4

5

6

7

- 12V +

T1

T2

C

NC

EOL

Reviews: