background image

Installation Instructions

LC-101CAM 

Series Mono/Colour

Quad Element PIR Mono/Colour Camera
Motion Detector with Pet Immunity

Video sensing device 

High sensitivity and high resolution board camera. 

Electronic shutter control.

Audio sensing device 

Omnidirectional response.

H igh sensitivity.

FIG  1  

- Knockout h oles

FIG 3 

- Lens pattern

TYPICAL INSTALLATION

Select mounting location

C hoose a location most likely to intercept an intruder. (Our recommendation is a corner installation). See detection pattern (Fig.3). The quad-
element high quality sensor detects motion crossing the beam; it is slightly less sensitive detecting motion tow ard the detector. The LC -101CAM
performs best when provided with a constant and stable environment.

Avoid the Following Locations

 *

 Facing direct sunlight. 

*

 Facing areas that may change temperature rapidly. 

*

 Areas where there are air ducts

o r  s ubs ta ntia l  ai r flo w s. 

T h e  LC - 10 1C A M  per fo rm s  b etter   w h en  pr ov i ded  w ith  a   co ns tant  a nd  s tabl e  en vi r onm ent.

MOUNTING DETECTOR BASE

1.

 To remove the front cover, unscrew the holding screw  and gently raise the front cover. Fig.2-12 

2.

 To remove the PC board, carefully unscrew

the holding screw  located on the PC  board. Fig.2-7 

3.

 Put wire through the bracket and holes “A”. Fig.1 

4.

 Mount the detector base to the wall

or on the ceiling with a suitable bracket. (Install bracket). 

5.

 Reinstall the PC board by fully tightening the holding screw. Connect wire to terminal

block. Fig.5 

6.

 C onnect the camera cable to connector in PC 

7.

 Replace the cover by inserting it back in the appropriate closing pins and screw

in the holding screw.

DETECTOR INSTALLATION

Terminal Block Connections 

(See Fig.5)

Terminals 1 & 2 - Marked “T1,T2” (TAMPER)

 If a Tamper function is required connect these terminals to a 24-hour normally closed protective

zone in the control unit. If the front cover of the detector is opened, an immediate alarm signal w ill be sent to the control unit.

Terminals 3 & 4 - Marked “AU DIO: OUT, GND” 

This is the audio signal output. These two terminals should be connected to an audio input.

Terminals 4 & 5 - Marked “VIDEO: GND, OUT”

 This is the video signal output. These tw o terminals should be connected to video input.

Term inals 6,7 & 8 - Marked “RELAY: N O, COM & NC”

 These are the output relay contacts of the detector. Connect to a normally closed or

normally opened zone in the control panel.

Terminal 9 - Marked “-” (GND)

 C onnect to the negative Voltage output or ground of the control panel.

Term inal 10  -  Marked   “+  “( +12V)

  Connect  to a  positive  Voltage output  of  8.2  -16Vdc  source  (usually  from  the alarm control  unit)

FIG 2 

-  Detector Installa tion

FIG 4 

- Terminal block

15m

B

A

A

1

3

7

5

4

6

12

7

10

8

9

11

AUDIO

VIDE O

RELAY

1

2

3

4

5

6

7

8

9

OUT

- 12V  +

T1

GND

T2

C

NC

N.O

OUT

10

A  n ew  g en erat ion   o f  p rofessio nal  mo vem en t  sp read  analyzing   PIR  detectors  w ith   Mo no  /  Co lo ur  C amera

Reviews: