Installation Instructions

LC-103PIMSK

Professional Passive Infrared & Microwave Detector
with Anti-Mask with Pet Immunity

The detector provides an analysis of environmental conditions through the entire movement speed frequency spectrum,
allowing focus on intruders and eliminating environmental factors of false alarms. The spectrum analysis is embedded
in the VLSI based electronics of the detector assuring high reliability and trouble free operation. Unique function - anti-
mask - guarantees detector protection from non desirable approach and any kind of masking beginning from the distance
0.8m and closer.

As the LC-103PIMSK is a combined technology (PIR  & microw ave) an alarm signal relay activation occurs only when signals
from both sensors (PIR & MW) are present at the same time. The effective detection range is the range of which the patterns
(PIR & MW) are intersected. The GAIN potentiometer adjustment changes the MW signal intensity so that the effective pattern
will be scaled.
Unique function - anti-mask - guarantees detector protection from non desirable approach and any kind of masking beginning
from the distance 0.8m and closer.

FIG  1  

- Knockout h oles

C

C

A

B

B

B

B

A

A

D

D

C

C

C

TYPICAL INSTALLATION

Select mounting location

C hoose a location most likely to intercept an intruder. (Our recommendation is a corner installation). See detection pattern (Fig.3). The quad-
element  high  quality  sensor  detects  motion  cr os sing  the  beam;  it  is  slightly  less  sensitive  detecting  motion  tow ard  the  detector.
The LC-103PIMSK performs best when provided with a constant and stable environment.

Avoid The Following Locations: 

*

 Facing direct sunlight. 

*

 Facing areas that may change temperature rapidly. 

*

 Areas where there are air

duc ts   or   s ubs tanti al  air flow s. 

T he  LC - 103PIMSK  perform s  better  w hen  pr ovided  wi th  a  c onstant  and  stable  env ironment.

N O TE : 

LC -103  PIMSK  br eaks  off  Anti-M ask  alar m  s ignal  only  after  rec eivi ng  s ignal  from  PIR ’  but  not  l essthan  30  s ec.

MOUNTING DETECTOR BASE

1.

 To remove the front cover, unscrew the holding screw and gently raise the front cover. (Fig.2-11) 

2.

 To remove the PC  board, carefully unscrew

the holding screw located on the PC board.(Fig.2-9) 

3.

 Break out the desired holes for proper installing (Fig.1-B or C). 

4.

 The circular and

rectangular indentations at the bottom base are the knockout holes for w ire entry. You may also use mounting holes that are not in use for running
the wiring into the detector.(For option with bracket - lead wire through the bracket, Fig2-7) 

5.

 Mount the detector base to the wall, corner or

ceiling. (For option w ith bracket install bracket).(Fig.6,Fig.7) 

6.

 Reinstall the PC board by fully tightening the holding screw. Connect wire to

termi nal  block . 

7.

  R epl ac e  the  cov er   by  inserting  it  back  in  the  appropri ate  closing  pi ns  and  s crew   i n  the  holding  sc rew.

DETECTOR INSTALLATION

Terminal Block Connections 

(See Fig.4)

Terminals 1 & 2 - Marked “T1,T2” (TAMPER) 

If a Tamper function is required connect these terminals to a 24-hour normally closed protective

zone in the control unit. If the front cover of the detector is opened, an immediate alarm signal w ill be sent to the control unit.

Terminals 3 & 4 - Marked “A M: N C, C ” 

 These are the output relay Anti Mask contacts of the detector. Connect to a normally closed zone in

the control panel.

Terminal 5 - Marked “EOL” -

 End of line option.

Terminals 6 & 7 Marked “PIR: NC, C” 

These are the output relay PIR contacts of the detector. Connect to a normally closed zone in the control

panel.

Terminal 8 - Marked ”-” (GND)

 C onnect to the negative Voltage output or ground of the control panel.

Term in al  9  -  Marked  “+”  ( +12V)

  C onnect  to  a  positive  Voltage  output  of  8.2  -16Vdc  source  (usually  from  the  alarm  control  unit).

FIG 2 

-  Detector Installa tion

FIG 4 

- Terminal block

11

6

5

8

4

10

9

1

3

7

1

2

3

4

5

6

7

8

9

-  12V +

T1

EOL

T2

C

NC

C

NC

AM

PIR

FIG 3 

- Lens pattern

15m