background image

Installation Instructions

LC-105DGB

Shock & Glass Breakage Detector

LC-105DGB belongs to the new generation of glass breakage detectors. The LC-105DGB can detect glass cutting by diamond in addition
t o   t h e   im p r o ved   de t ect io n   o f  g las s  b r eak ag e.   T h is  is  ach ie ved   b y  o u r   n ew   all- d ig it a l  si g n al  p r o ces sin g

.

The LC -105D GB offers the solution for the false-alarms problem. The LC-105DGB detects the unique patterns of sound emitted by breaking or
cutting glass. The LC -105DGB does not have to be attached to the window, providing volume protection, and allows the protection of several
windows using one detector.

Fig. 1  

- Dete ctor Mo unnting

Fig. 4 

- Termina l blo ck

1

2

3

4

5

6

TAMPER

- 12V  +

RELAY

A

A

Fig. 2 

- Detecto r Instal latio n

TYPICAL INSTALLATION

Mounting

The detector offers flexible installation. It can be either ceiling mounted or wall mounted as shown in Fig. 1.

Selecting mounting location

If heavy blinds or curtains cover the glass, you must locate the detector behind the blinds on the window frame or above it, otherwise the blinds
might block the sound. Make sure to test the unit thoroughly using a glass break simulator for proper detection. Install the detector in a direct
line of sight with the protected glass. Do not mount the unit in front of air ducts, or close to bells (measuring 0.5m or larger in diameter). For
pr otecting  s everal  w indow s  i n  one  room,  locate  the  detec tor   at  opti mal  distance  from  them  to  achi ev e  the  bes t  detec tion.

Note:

 for symmetrical cover of the detection area it is recommended to place the detector on the ceiling.

CONN ECTIN G THE D ETECTOR

 (Fig. 2,3&4)

1. 

Use a small screwdriver to release the top of the case and lift open the case (Fig. 3-1,2) There is no need to remove the PC B (Printed Circuit

    Board) from the case).

2.

 Insert the wires through the w iring hole (Fig. 3-3).

3.

 Use the mounting holes (Fig. 2-A) to mount the detector.

4.

 Connect the wires to the terminal. (Fig.4).

5.

 Close the case.

JUMPERS

LED ON: 

  

LEDS enabled

LED OFF:

   LEDS disabled

Shock ON: 

  This is the normal working mode. Both breaking glass sound and breaking glass shock-wave

are necessary for generating an alarm.

Shock OFF:

This  mode  i s  used  only  for  ins tallation  settings.  The  sound  of  breaking  glass   is  enough  to  generate  an  alarm.

WIRE CONNECTIONS
Terminal Block Connections

 (See fig. 4).

Terminal 1 (Marked "-").

 Connect to the return Voltage or ground of the control panel.

Term in al  2  ( Marked   "+") .

  C onnec t  to  the  posi tive  Voltage  of    9- 16  VD C   sour ce  (us ually   fr om  the  alar m  control   unit).

Terminals 3 & 4 (Marked TAMPER ).

 If a Tamper function is required connect these terminals to a 24 hours normally closed protective zone in

the  c ontr ol  unit.  If  the  fr ont  cover   of  the  detector   is  opened,  an  imm edi ate  alarm  signal  wi ll  be  sent  to  the  c ontr ol  unit.

Term in als  5  &   6  ( Marked   R E LAY) .

  T hese  ar e  the  output  relay   c ontacts  of  the  detector.  Stand  by  -  N .C   /  A larm   - N .O

Fig. 3 

- Detector Insta llation

4

2

1

3

Reviews: