Fig. 6
- Detector test
Fig. 5
- PCB Layout
BLOCK CONNECTOR
LIMITED WARRAN TY:
Digital Security Contr ols Ltd, w arr ants that for a period of 12 m onths from the date of pur chase, the product shall be fr ee of defe cts in mater ials and wor km anship unde r nor mal use a nd that in
fulfillment of any br each of such warr anty. D igital Security Contr ols Ltd shall, at it s opt ion, r epair or re place the defective equipment u pon ret urns of the e quipm ent to its repair d epot. This war ranty applies only to de fects
in parts and workmanship and no t to damage incur red in shippin g or ha ndling, or damag e due to causes beyond the contr ol of Digit al Secur ity Con trols Ltd, such as lightning, excessive voltage me chan ical sho ck, wate r
damage, or damage arising out o f abuse, alter ation or impr oper a pplication of the equipment.
The forego ing w arr anty sh all apply only to the or iginal buyer, and is and shall be in lieu of any and all o ther w arr anties, whether expressed or implied and o f all othe r obligations o r lia bilities on th e part of Digital Secur ity
Contr ols Ltd . Digital Security Contr ols Ltd neith er assumes responsib ility for , nor au thorizes an y oth er per so n purpo rting to act on its behalf to modify or t o cha nge this w arr anty, nor to assume for it a ny ot her w arr anty or
liability concer ning this pr oduct.
In no event shall Digita l Secur ity Con trols Ltd be lia ble f or any direct, indirect or conseq uential da mages, lo ss of anticip ated pr ofits, loss o f time or an y oth er losses incurr ed by the buyer in conne ction with th e purchase,
in stallation or oper ation or failure of t his pro duct.
Motion det ecto rs can only detect mo tion within the de signated are as as Sh own in th eir re spe ctive inst allation instructions. Th ey can not discr iminate betwe en intrud ers and inte nded occupants. Mot ion detectors do not
provide vo lumetr ic ar ea prote ction. The y have multiple bea ms of d etection and mo tion can only be detected in unobstructed area s covered by these beams. They cannot detect motion which occur s beh ind w alls, ceilings,
flo or, closed door s, g lass partitions, g lass doors or windows. Any
type of tamper in g whe ther in tentional or unintentional such as m asking , painting, or spra ying of any ma terial on the lenses, mirr ors, windows or any o ther part of th e detection system w ill impair its pr oper oper ation.
Passive infr ared motion detectors oper ate by sensing changes in temper atur e. Howe ver their effectiven ess can be r educed when the ambient temper atur e rises ne ar or above body temper ature or if ther e are intentional
or u nin ten tion al so ur ces of he at in or n ea r th e d et ectio n a r ea. So me of t hese h eat so ur ces could be h ea ter s, r adia tor s, sto ves, bar b equ es, fir ep laces, su nligh t, stea m vent s, lig ht in g and so o n.
WARNI NG: Di git al Securit y Co nt rols Ltd , reco mm end s t hat th e en tire sys tem be com plet ely t ested o n a reg ula r basis. However, d espit e f re qu ent test ing , an d d ue to , bu t n ot lim ited to , crim inal t am perin g
or elect rical d isru pt ion , it i s po ssible f or t his p rod uct to fail t o p erfo rm as exp ecte d.
Im p ort an t in f orm a tio n : Ch an g es or mo d if ica ti on s no t ex pre ssl y ap p ro ved b y D ig it al Secu ri ty Co n tro ls L td c ou ld v oi d t h e u se r's a ut h or it y t o op er at e t hi s e qu ip m en t.
2005 Digital Security Controls Ltd
Toronto, Canada
www.dsc.com
TESTING THE DETECTOR
Set the jumpers as follows:
LED =ON, SHOCK=ON.
1.
Use the simulator in manual mode to simulate the noise of glass breaking . Check that the yellow LED is ON. If it does not light, a sensitivity
calibration is necessary. Rotate the "SEN S" potentiometer clockwise to increase the sensitivity, and counterclockwise to decrease it.
2.
Use your
hand or a padded object to firmly strike on door or table. If the green LED does not light, adjust the sensitivity as necessary.
3.
Use the Simulator
in automatic mode and check that the red LED lights. If the red LED, yellow LED and green LEDS are ON, your detector is w orking properly.
*
Cutting of glass by a diamond causes only the red LED to light. If the red LED does not light try adjusting the sensitivity until the red LED lights.
FINAL TESTING
*
Set the jumpers as follows:
LED =ON, SHOCK=OFF.
*
To ensure maximum protection against false alarms, activate any device in the area, w hich might automatically activate, like cycle pumps,
generator s, heating/ai r conditioni ng units , etc. If thes devi ces trigger an alar m, mount the unit i n a different location.
*
Set the jumpers to their normal working position: SHOCK = ON.
WIRE SIZE REQUIREMENTS
U se #22 AWG (0.5mm) or wires w ith a larger diameter. Use the following table to determine required wire gauge (diameter) and length of the
wire between the detector and the control panel.
TECHNICAL SPECIFICATION
Power Input
9-16VDC
Current
Standby:
15mA at 12 Vdc
Consumption
Active:
40mA at 12Vdc
Detection Range
10m (33ft), Max.
Cutting 3m
Mounting
Ceiling or Wall
Alarm Output Relay
N.C. 50mA/24Vdc
10 Ohm in line resistor
Tamper Switch
N.C. 50mA/24Vdc with
10Ohm in line resistor
Operating
-20
o
C to 50
o
C
Temperature R ange
(-4
o
F to 122
o
F)
Operating Humidity
95% max relative humidity
Range
non condensing
Storage
-30
o
C to 70
o
C
Temperature R ange
(-22
o
F to 158
o
F)
RFI Protection
30V/m 10 -1000 MHz
EMI Protection
50,000V electrical
interference from lightning
Dimensions
79mm x 48mm x 21mm
Weight
40gr. ( 1.41oz.)
Wire Length
m 200 300 400 800
Wire Diameter
mm .5 .75 1.0 1.5
Wire Length
ft 800 1200 2000 3400
Wire Gauge
# 22 20 18 16