background image

14

T E S T I N G  &  M O U N T I N G

If you move the LCD5501Z32-900, repeat the tests
described in sections 5.1 and 5.2 on all the wireless
devices. Continue to test the devices until you
h a v e   f o u n d   s a t i s f a c t o r y   l o c a t i o n s   f o r   t h e
LCD5501Z32-900 and the WLS904, WLS905,
WLS906 and WLS907 devices, and there is good
reception between the LCD5501Z32-900 and the
WLS908, WLS909 and WLS910 devices.

Mount the WLS904, WLS905, WLS906,
WLS907, and WLS915 Devices

If you have conducted the placement test described
in section 5.1 and got 3 “Good” or “Fair” results in a
row for each device, you can mount the wireless
devices. See the Installation sheet for each device
for mounting instructions.

5.3 Battery Test for WLS908 Panic
Pendants

You cannot test Panic Pendant batteries using the
methods described in sections 5.1 and 5.2. You must
program panic pendant zones before you can test
the panic pendants.

NOTE: If a low battery condition is detected, you must
immediately replace the unit.

Follow these steps to test panic pendants:

1. Begin testing when your system is in the ready

state and the keypad Ready light is on.

2. Go to an LCD keypad.

NOTE: If your system is partitioned, you can only view
the Panic Pendant test result on a partition LCD
keypad. To view the test result on a global LCD key-
pad, you must “loan” the keypad to the partition before
you begin the test. See your Installation Manual for
information on global and partition keypads.

3. Press and hold the “Test” button on the pendant

for two seconds.

4. If the pendant’s battery condition is 

normal, the

Ready light on the LCD keypad will turn OFF for
30 seconds or until the [#] key is pressed. On the
PC5010, PC5015, PC5008, PC1555 and PC580

v2.x or higher: If the pendant’s battery condition
is normal, the keypad will beep and the LCD
keypad will display “System Test in Progress.”
If the pendant’s battery is 

low, the LCD keypad’s

Trouble light will turn ON and the keypad will give
a series of continuous beeps.

Instruct the user(s) to perform this test when they
perform the weekly system test.

NOTE: If a low battery condition is detected, you must
immediately replace the unit.

Replacing a Pendant with a Low
Battery

You should immediately replace a pendant when a
low battery is indicated. To replace a pendant on the
system, follow these steps:

From the keypad:

1. Enter [

][8][Installer Code].

2. Enter programming Section [804].

3. Enter the 2-digit zone number of the pendant to

be replaced (01-32).

4. Enter serial number [000000].

5. Re-enter the 2-digit zone number for the pendant

being replaced.

6. Enter the ESN of the new pendant.

7. To exit press [#] twice.

Through downloading:

1. Connect to the control panel through

downloading.

2. Upload window contents of the zone serial

numbers in the wireless expansion section of
downloading.

3. Change the serial number of the pendant to be

replaced to [000000].

4. Download window contents.

5. Enter the ESN of the new pendant.

6. Download window contents.

Summary of Contents for LCD5501Z32-900

Page 1: ...LCD5501Z32 900 WARNING Please refer to the System Installation Manual for information on limitations regarding product use and function and information on the limitations as to liability of the manuf...

Page 2: ...her warranties whether expressed or implied including all implied warranties of merchantability or fitness for a particular pur pose And of all other obligations or liabilities on the part of Digital...

Page 3: ...s 8 3 4 Identified Wireless Keys 8 3 5 Enrolling Programming Handheld Keypads 9 3 6 Deleting Wireless Devices 10 Section 4 Other Programming 11 4 1 Program Zones and Partitions 11 4 2 Enable Receiver...

Page 4: ...her Specifications and Features Current Draw 260mA Frequency 922 to 926 MHz Spread Spectrum Zones receiver can receive signals from up to 32 wireless zones Supervisory programmable supervisory window...

Page 5: ...ne wire from the device to the Z terminal and the other wire from the device to the B black terminal For powered devices run the red wire to the R positive terminal and the black wire to the B negativ...

Page 6: ...02 The panel will now supervise all assigned keypads and enrolled modules on the system To review which modules the control panel is currently supervising 1 Enter 8 Installer s Code 2 Enter 903 to dis...

Page 7: ...You can change the function of each key on every keypad Please see your system s Installation Manual for instructions on programming the keys and a complete list of all the function key options availa...

Page 8: ...ou are finished press to exit 2 6 Door Chime Options You can program the LCD5501Z32 900 keypad to sound a tone when any zone is opened or closed There are two parts to the LCD5501Z32 900 door chime pr...

Page 9: ...he door chime sounds 1 Enter 8 Installer s code 2 Enter to go to door chime sound programming 3 Enter a 2 digit number for the zone you want to program 01 32 4 Turn one of the following options on by...

Page 10: ...ition programming see section 4 Enroll Program Devices This section describes how to enroll and program wireless devices using zones WLS904 WLS905 WLS906 WLS907 WLS908 and WLS915 wireless keys WLS909...

Page 11: ...you press and hold one of the four buttons for two seconds the system will execute the programmed function For systems not using partitions program the function buttons in section 59 All wireless key...

Page 12: ...med as 7 1 4 in sections 141 to 154 3 5 Enrolling Programming Handheld Keypads WLS910 For handheld keypads to work on the system you need to enroll them and then program the function buttons You can e...

Page 13: ...uttons or for partition 2 function buttons 4 For each of the 4 function buttons enter the 2 digit number of the function you want to select See the programming worksheets for a list of function button...

Page 14: ...nes to be su pervised If normally Closed or Single EOL resistors are selected the PC5010 will not be able to supervise the wireless devices If a wireless device stops S E C T I O N 4 Other Programming...

Page 15: ...Enter the 2 digit number of the RF Jam Detect zone 01 to 32 in the programming section 4 Disable supervision for the RF Jam detect zone by turning the relevant option off in section 82 83 84 or 85 Se...

Page 16: ...the device 6 Read the test results at the keypad Result LED Keypad LCD Keypad Buzzer Bell Good Light 1 On Steady Good 1 Beep Squawk Fair Light 2 On Steady Fair 2 Beeps Squawks Bad Light 3 On Steady Ba...

Page 17: ...your Installation Manual for information on global and partition keypads 3 Press and hold the Test button on the pendant for two seconds 4 If the pendant s battery condition is normal the Ready light...

Page 18: ...Device Low Battery trouble The user should be instructed to test this device every week See section 5 4 for testing instructions The system will delay reporting the event to the central station for t...

Page 19: ...or more information on testing devices Verify that you are testing the correct zone Verify that the correct ESN was entered when the device was enrolled Verify that the device is in range of the LCD55...

Page 20: ...00 Keypad Options Default Option On Off ON I _ ___ ____I 1 Local Clock Display Enabled Local Clock Display Disabled ON I _ ___ ____I 2 Local Clock Displays AM PM Local Clock Displays 24 hour Time OFF...

Page 21: ..._ I I _ _ _ _ _ _ _ _ I I _ _ _ _ _ _ _ _ I 16 I _ _______ __________________________________________________________I I _ _ _ _ _ _ _ _ I I _ _ _ _ _ _ _ _ I I _ _ _ _ _ _ _ _ I I _ _ _ _ _ _ _ _ I 1...

Page 22: ...10 l_____l_____l_____l_____l_____l_____l 11 Zone 11 l_____l_____l_____l_____l_____l_____l 12 Zone 12 l_____l_____l_____l_____l_____l_____l 13 Zone 13 l_____l_____l_____l_____l_____l_____l 14 Zone 14 l...

Page 23: ...__l_____l_____l_____l_____l 52 Key 12 l_____l_____l_____l_____l_____l_____l 53 Key 13 l_____l_____l_____l_____l_____l_____l 54 Key 14 l_____l_____l_____l_____l_____l_____l 55 Key 15 l_____l_____l_____...

Page 24: ...unction Key 2 l____l____l Function Key 4 l____l____l Supervision 81 Wireless supervisory Window Default 03 l____l____l wireless device window hours valid entries are 01 24 NOTE Panic pendants are NOT...

Page 25: ...Disabled l________l Option 2 Zone 18 Supervision enabled Disabled l________l Option 3 Zone 19 Supervision enabled Disabled l________l Option 4 Zone 20 Supervision enabled Disabled l________l Option 5...

Page 26: ...Key 05 on partition 2 On partition 1 l________l Option 6 Wireless Key 06 on partition 2 On partition 1 l________l Option 7 Wireless Key 07 on partition 2 On partition 1 l________l Option 8 Wireless K...

Page 27: ...detector should be located on each story of the living unit Figure 2 In the family living units with more than one sleeping area a smoke detector should be located to protect each sleeping area Figure...

Page 28: ...ke detectors that are a part of this system may not properly alert occupants of a fire for a number of reasons some of which follow The smoke detectors may have been improp erly installed or positione...