PC4O2OKT  Version 1.0CAP

Book 1

System Manual

®

• W A R N I N G •

This manual contains information on limitations regarding product use and function and information

on the limitations as to liability of the manufacturer. The entire manual should be carefully read.

Summary of Contents for MAXSYS PC4020NK

Page 1: ...1 System Manual W A R N I N G This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manu...

Page 2: ...roperly in order to provide adequate protection Every installation should be evaluated by a security professional to ensure that all access points and areas are covered Locks and latches on windows an...

Page 3: ...anel 6 Programming the System 6 Hardware Reset of Memory to Factory Defaults 7 PC4020 Main Board Specifications_______________________________________ 8 Control Panel 8 Output Voltage 8 Remote Keypad...

Page 4: ...5 Walk Test 6 Walk Test Code 25 Utility Output 7 or 7 Access Code 25 Installer s Programming Commands 8 Installer s Code 25 At Home Arming 9 Access Code 25 Quick Arm 0 25 Quick Exit 0 When Armed 25 Ke...

Page 5: ...n panel processes signal information and communicating with the monitoring station The main panel is capable of supervising 16 zones any of which may be defined for fire or burglary applications and a...

Page 6: ...PC4003C 1 module PC4004C Attack resistant for PC4020 plus 2 modules PC3000 PC4820 Supervised Alarm Output Bell Output 700 mA fused at 5 Amps 12 VDC commercial and 11 6 12 6 VDC residential Steady or...

Page 7: ...ll allow the partition setup done without mistakes Locate any zone expansion modules PC4108 or PC4116 required close to groups of zones for easier wiring Decide on the order to enroll the expansion mo...

Page 8: ...te the zone may require to be tripped more depending on the location of the zone On the restoral of the zone for the second time the panel will display a rating of the zones placing with respect to RF...

Page 9: ...zed For example if the microprocessor on the module has been scrambled due to a transient the PC4020 will power down the COMBUS the PC4204 will mimic the PC4020 and cut off its power supply to the mod...

Page 10: ...ily available Once all modules are enrolled perform a diagnostics check on the panel to determine if any problems are present see Diagnostics Programming the System The PC4020 has the capability to op...

Page 11: ...light on the keypad If it is on press then 2 to determine the trouble The Trouble Display section in Keypad Functions gives a description of the different trouble conditions Step 5 Instructing the End...

Page 12: ...nternal clock locked to AC power frequency or optional crystal time base Switched Auxiliary Supply Output Programmable for 1 of 35 options 11 6 12 6 VDC 300 mA maximum Battery 12 volt 4 Ah minimum rec...

Page 13: ...s Low COMBUS supervision to the PC4020KT AUX output provides 125mA supply power at 13 8V Provides Lock output supervision to the PC4020 Provides Reader power supervision to the PC4020 PC4108 Expansion...

Page 14: ...OF LINE RESISTOR ANY Z TERMINAL ANY COM TERMINAL TYPICAL ZONE CIRCUITS TELEPHONE CONNECTION GROUND CONNECTION 120 V 40 VA TRANSFORMER 16 18 V 40 VA DO NOT CONNECT TO RECEPTACLE Nut Washer Cabinet Bolt...

Page 15: ...11 Module Hookup Diagram...

Page 16: ...IS REQUIRED FOR RESIDENTIAL FIRE ALARM SYSTEMS SW AUX PROGRAMMED FOR SENSOR RESET TO ANY COM TERMINAL TO ANY ZONE Z TERMINAL TO ZONE Z TERMINAL PROGRAMMED FOR FIRE TO ANY COM TERMINAL BELL LOOP 700 m...

Page 17: ...with controlled devices TERMINAL CONNECTIONS COMBUS Terminals RED BLK YEL and GRN Connect the red wire of the COMBUS to the RED terminal the black wire to the BLK terminal the yellow wire to the YEL...

Page 18: ...and jacks meet the dimension tolerance and metallic plating requirements of 47 C F R Part 68 Subpart F TIP Green wire Incoming line from RNG Red wire telephone company T 1 Brown wire Outgoing line to...

Page 19: ...An access code is a 4 or 6 digit optional number which will permit access to the system i e Arm Disarm control Installer s Programming etc User access codes are programmed in the User Programming sect...

Page 20: ...n Label Pressing the right arrow key displays the message SELECT 1 FOR OPTIONS If the selected partition is armed the LCD will prompt with the message SELECT 0 DISARM PARTITION If option 0 is selected...

Page 21: ...communicator program information The installer s program code may be changed by the installer Arming Close all protected doors and windows and stop movement in areas covered by motion detectors The E...

Page 22: ...displayed with the partition status at the right corner of the LCD To disarm the partition being viewed simply press or use the hot key 0 If 1 For Options is selected the user will be prompted with th...

Page 23: ...s If one of these conditions occurs the keypad TROUBLE indicator will light and the audible indication will sound two short beeps every 10 seconds When the key is pressed the audible indication will s...

Page 24: ...nicating COMBUS Low Pwr Modules are not getting enough voltage from the COMBUS Check for proper connection of COMBUS or the COMBUS needs to be repowered See 4204 modules and the 4204 PGM COMBUS power...

Page 25: ...ow battery condition To view which zone has the trouble press the key while viewing the trouble condition The zone s with the trouble condition will be displayed in numerical order on the display A ke...

Page 26: ...edule window is active unless a user with a Privileged card grants the user access to the system When the Second Card Schedule is not active out of window the user will be able to access the assigned...

Page 27: ...de will not operate on any partition 7 To Exit the menu press the key 2 User Name Search 1 This option will allow selection of the user to be programmed by searching using the user name To do this ent...

Page 28: ...ypad When this function is selected the Keypad Setup menu will appear on the keypad Bright Control adjusts the level of backlighting on the LCD display and the backlighting on the keys Contrast Contro...

Page 29: ...d P keys will activate for all active partitions any valid access code from any partition may silence the alarm Note See KEYPAD TOG OPT in the Programming Guide for changing keypad zones options The s...

Page 30: ...each door to allow access at only specific times of the day If the user is to have arming disarming abilities the user must be assigned to a partition and the installer must assign the door s arm dis...

Page 31: ...the access code names See ZONE LABEL in the Programming Manual for programming zone labels The printout will then be as Sample 3 The PC4400 sends events to the printer as they occur If the printer is...

Page 32: ...to the tip and ring terminals on the panel A DTS 1 must be connected to the lines and in the local mode Program the downloading access code and panel I D code Program a zone for Forced Answer See Zone...

Page 33: ...9 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 18...

Page 34: ...r 51 1 52 2 53 3 54 4 55 5 56 6 57 7 58 8 59 9 60 10 61 11 62 12 63 13 64 14 65 15 66 16 Indicated PC4700 Number Fire Module 67 1 Indicated VPM 2 Number Voice Prompting Module 68 1 Indicated PC4820 Nu...

Page 35: ......

Page 36: ...1997 2002 Digital Security Controls Ltd Toronto Canada www dsc com Technical Support 1 800 387 3630 Printed in Canada 29002586 R0...