5
02EE - 032D
Wireless Zone Supervisory
18/98
151 - 214
Supervi
032E - 0335
Partition Police (1 - 8)
◆
19/99
001 - 008
Burglary Verified
0336-0337
For Future Use
00
—
Not Transmitted
0338
DVAC Line Fault
3E/BE
004
Line
0339
DVAC Module Fault
32/B2
137
System Trb
033A
DVAC Shut Down By C.S.
32/B2
138
System Trb
033B
Bypassed Zone
■
*
001 - 128
(See Zone Events Section)
033C-0346
For Future Use
00
—
Not Transmitted
◆
Partition Police Code restoral not transmitted by DVAC module.
■
To disable this transmission, program the function byte as “00” and the reporting code as “000”. Programming any
other values will result in the transmission of the default settings.
If the reporting code is left as default FF, it will be the same as the zone number and the function byte for the zone events will
be the corresponding zone type. A zone has seven associated events that will modify the printer message.
The following is a list of changes of DVAC reporting codes that apply to the PC40x0 v3.0 only.
Rep #
Title
FB
RC
Printed Message
1CA
Fire Key Alarm/Restores
00
129
Fire Alm/Rst Zn#129
1CB
Aux. Key Alarm/Restore
04
129
Medical Alm/Rst Zn#129
1CC
Panic Key Alarm/Resotres
02
129
Panic Alm.Rst Zn#129
24E
Quick Arm
F6
130
Not Transmitted
24F
Partial Close
7E
004
Partial Closing
278-2A7
PC4204 Battery Trouble/Restore
3D/BD
011-026
Not Transmitted
PC4204 AC Trouble/Restore
3A/BA
011-026
Not Transmitted
PC4204 Aux. Supply Trb/Restore
3C/BC
011-026
Not Transmitted
2EE-32D
Wireless Zone Supervisory
18/98
151-214
Not Transmitted
338
DVAC Line Fault
3E/BE
004
Not Transmitted
339
DVAC Module Fault
32/B2
137
Not Transmitted
33A
DVAC Shut Down by C.S.
32/B2
138
Not Transmitted
Zone Events
PC4020 Event
DVAC Printer MSG
PC4020 Event
DVAC Printer MSG
Zone Alarm. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Alm
Zone Trouble/Tamper Restore. . . . . . . . . . . . . . . . . .T_R
Zone Restore. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rst
Zone Fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sup
Partial Zone Alarm . . . . . . . . . . . . . . . . . . . . . . . Byp
Zone Fault Restore. . . . . . . . . . . . . . . . . . . . . . . . . . . . S_R
Zone Trouble/TamperTrb. . . . . . . . . . . . . . . . . . . . . . . . . . . Trb
The following is a list of the default settings for zone transmissions:
Zone Type FB:
Alm
Rst
Byp
Trb
T_R
Sup
S_R
Printer MSG
Standard Delay
08
88
48
28
A8
68
E8
Delay
Aux. Delay
08
88
48
28
A8
68
E8
Delay
Instant
09
89
49
29
A9
69
E9
Instant
Interior
0A
8A
4A
2A
AA
6A
EA
Interior
Interior H.A
0B
8B
4B
2B
AB
6B
EB
InteriHA
Delay H.A
07
87
47
27
A7
67
E7
DelayHA
24 hr Bell *
11
91
51
31
B1
71
F1
24 hr
24 hr Bell/Buzzer
11
91
51
31
B1
71
F1
24 hr
24 hr Buzzer
11
91
51
31
B1
71
F1
24 hr
Standard Fire
00
80
40
20
A0
60
E0
Fire
Delayed Fire
00
80
40
20
A0
60
E0
Fire
Auto Ver. Fire
00
80
40
20
A0
60
E0
Fire
Momentary Arm
XX
Maintained Arm
XX
Latching 24 hr
16
96
56
36
B6
76
F6
24hrLat
Forced Answer
XX
Links Supervisory
18
98
58
38
B8
78
F8
Supervi
Links Answer
XX
Sprinkler
01
81
41
21
A1
61
E1
Sprnklr
Hold Up
03
83
43
23
A3
63
E3
Hold Up
Panic
02
82
42
22
A2
62
E2
Panic
Technical
18
98
58
38
B8
78
F8
Supervi
* The following zone types transmit as 24 hr Bell: 24 hr Gas, 24 hr Heat, 24 hr Medical, 24 hr Emergency, 24 hr Water, 24 hr Freeze.
5 .
P r o g r a m m i n g t h e M o d u l e