PROGRAMMING WORKSHEETS
NOTE:
In sections
to
do not enter data into sections that are not used.
Phone
Number
Page
Enter [0] for the digit 0 in the phone number. Enter
(HEX D) for additional dial tone detection
between number digits, as in local PBX systems. Enter
to end the phone number entry
Customer
Account
Code
Page
14
Enter
(HEX A) for the digit “0” in the account code. For a 3-digit code, enter [0] for the 4th digit.
2nd Phone Number Page 14
2nd Customer Account Code
Page 14
Zone Alarm Reporting Codes
Page
For single digit reporting codes, enter [0] as the second digit.
Default
Zone 1 Alarm Enter
(HEX A) to transmit a
(zero = pulses)
Zone 2 Alarm
Zone 3 Alarm
Zone 4 Alarm
Zone
Reporting Codes
Page 15
For single digit reporting codes, enter [0] as the second digit.
Default
Zone 1
Enter
(HEX A) to transmit a
(zero = 10 pulses)
Zone 2
Zone 3
Zone 4