30
Alarm Cancelled:
this reporting code will be sent if a valid
access code is entered during the Alarm Cancel window.
If a valid access code is entered during this window, then
the Alarm Cancelled event is logged and sent. When the
central station has acknowledged this reporting code/
event, a keypad ring-back will occur.
[329] - Priority Alarm and Restoral Reporting
Codes
[F], [A], [P] Alarm:
this reporting code will be sent if the
[F] [A] or [P] key is used to generate manual alarms.
Auxiliary Input Alarm:
this reporting code will be sent
when PGM2 is being used for 2-wire smoke detectors and
the 2-wire smoke detector goes into alarm.
[F], [A], [P] Restoral:
this reporting code will be sent after
the [F] [A] [P] alarm reporting code is sent.
Auxiliary Input Restoral:
the panel will transmit this
reporting code when the 2-wire smoke detector has
restored after an alarm.
[330]-[331] - Tamper Reporting Codes, Zones 1-32
If the panel is programmed for Double EOL zones (see
Section 2.10 "Zone Wiring") the panel will report a
Zone
Tamper Alarm
reporting code if an open condition is
present on a zone. A different reporting code can be pro-
grammed for each zone for identification.
[334]-[335] - Tamper Reporting Codes, Zones 1-32
The
Zone Tamper Restoral
reporting code will be trans-
mitted immediately when the Tamper condition is
restored.
[338] - Miscellaneous Tamper Reporting Codes
General System Tamper:
General System Tamper:
General System Tamper:
General System Tamper:
a General System Tamper
General System Tamper
General System Tamper
General System Tamper Report-
ing code will be transmitted when the tamper zone on
any module is violated.
General System Tamper Restoral:
General System Tamper Restoral:
General System Tamper Restoral:
General System Tamper Restoral:
the General System
General System
General System
General System
Tamper Restoral
Tamper Restoral
Tamper Restoral
Tamper Restoral reporting code will be transmitted when
the tamper zone on the module is restored.
Keypad Lockout:
Keypad Lockout:
Keypad Lockout:
Keypad Lockout: the panel will transmit the Keypad
Keypad
Keypad
Keypad
Lockout
Lockout
Lockout
Lockout reporting code if the lockout is activated.
[339]-[340] - Closing (Arming) Reporting Codes,
Access Codes 1-32
The panel will transmit a Closing
Closing
Closing
Closing reporting code to indi-
cate the system is armed. A different reporting code can
be transmitted for each User Code, Partition Master Code
and System Master Code to identify who armed the sys-
tem.
[341] - Miscellaneous Closing (Arming) Reporting
Codes
Closing by Duress Code 33/34:
a Closing by Duress
Closing by Duress
Closing by Duress
Closing by Duress code
Reporting code will be transmitted in addition to the
Duress reporting code if the system is armed using a
Duress Code.
Closing by Master or Supervisory Code:
the panel will
transmit a Closing
Closing
Closing
Closing reporting code to indicate the system
is armed. A different reporting code can be transmitted
for each User Code, Supervisory Code and System Master
Code to identify who armed the system.
Partial Closing:
a Partial Closing
Partial Closing
Partial Closing
Partial Closing reporting code will be
transmitted if the system is armed with zones manually
bypassed. The code will also be transmitted if the system
Auto-arms with zone(s) in violation.
Special Closing:
a Special Closing
Special Closing
Special Closing
Special Closing reporting code will be
transmitted if tthe system is armed using any of the fol-
lowing methods:
Quick Arm
Auto-arm
Arming via the DLS Software
Arming via Keyswitch
Away Function Key Arming
Arming with the Maintenance Code.
Stay Function Key arming
Late to Close
Late to Close
Late to Close
Late to Close
:
A Late to Close
Late to Close
Late to Close
Late to Close reporting code will be
transmitted if the system isn't armed before the auto-arm
start time when the late to close option, (Section 017,
option 5) is enabled.
Exit Fault:
If an Exit Fault Pre-Alert
Exit Fault Pre-Alert
Exit Fault Pre-Alert
Exit Fault Pre-Alert occurs and Entry
Delay expires before the system is disarmed, Exit Fault
will be logged and this reporting code will be sent.
[342]-[343] - Opening (Disarming) Reporting
Codes Access Codes 1-32
The panel will transmit an
Opening
reporting code
to indi-
cate the system is disarmed. A different reporting code
can be transmitted for each user code, the system master
code and system master code to identify who armed the
system.
[344] - Miscellaneous Opening (Disarming)
Reporting Codes
Opening by Duress Code 33/34:
Opening by Duress Code 33/34:
Opening by Duress Code 33/34:
Opening by Duress Code 33/34: This reporting code will be
transmitted in addition to the duress reporting code if the
system is disarmed using a Duress Code
Opening by Master or Supervisory Code:
Opening by Master or Supervisory Code:
Opening by Master or Supervisory Code:
Opening by Master or Supervisory Code: The panel will
transmit this reporting code to indicate the system is
armed. A different reporting code can be transmitted for
each User Code, Supervisory Code and System Master
Code to identify who armed the system.
Auto Arm Cancellation:
Auto Arm Cancellation:
Auto Arm Cancellation:
Auto Arm Cancellation: This reporting code is transmitted
when the Auto Arming sequence is canceled or Postponed
Special Opening:
Special Opening:
Special Opening:
Special Opening: A Special Opening
Special Opening
Special Opening
Special Opening reporting code will
be transmitted if the system is disarmed using any of the
following methods:
• Disarming using the Maintenance Code
• Disarming via the DLS Software
• Disarming via keyswitch
[345] - Maintenance Alarm Reporting Codes
Battery Trouble Alarm:
the panel will transmit a Battery
Battery
Battery
Battery
Trouble Alarm
Trouble Alarm
Trouble Alarm
Trouble Alarm reporting code when the backup battery
drops below 11.5 V
DC
.
AC Failure Trouble Alarm:
the panel will transmit an AC
AC
AC
AC
Failure Trouble Alarm
Failure Trouble Alarm
Failure Trouble Alarm
Failure Trouble Alarm reporting code when the AC to the
panel is lost and the AC Failure Communication Delay
timer expires.
Bell Circuit Trouble Alarm:
a Bell Circuit Trouble Alarm
Bell Circuit Trouble Alarm
Bell Circuit Trouble Alarm
Bell Circuit Trouble Alarm
reporting code will be transmitted immediately if an open
condition is measured on the Bell Output of the main
panel.
Fire Trouble Alarm:
a Fire Trouble Alarm
Fire Trouble Alarm
Fire Trouble Alarm
Fire Trouble Alarm reporting code
will be transmitted immediately when an open condition
is measured on any fire zone.
Auxiliary Power Supply Trouble Alarm:
the Auxiliary
Auxiliary
Auxiliary
Auxiliary
Power Supply Trouble Alarm
Power Supply Trouble Alarm
Power Supply Trouble Alarm
Power Supply Trouble Alarm reporting code will be
transmitted if the AUX output is shorted.
TLM Trouble:
a TLM Trouble
TLM Trouble
TLM Trouble
TLM Trouble reporting code can only be
transmitted if a LINKS1000/2X50 Communicator is being
used (see Section 5.26 LINKS1000 Cellular Communica-
tor). The panel will only transmit the signal after the time
programmed for the TLM Trouble Delay.
General System Trouble:
a General System Trouble
General System Trouble
General System Trouble
General System Trouble report-
ing code will be transmitted if the panel detects any of the
following:
AC Power Failure
Low Battery
AUX Output Trouble