38

The Download Access Code

Download Access Code

Download Access Code

Download Access Code and Panel Identifier Code

Panel Identifier Code

Panel Identifier Code

Panel Identifier Code

are for security and proper identification. Both the panel
and the computer file should have the same information
programmed before attempting to download.
The time to complete a successful download can be signif-
icantly reduced with the use of the PC-Link. This adaptor
makes it possible to perform on-site downloading. To Ini-

Ini-

Ini-

Ini-

tiate Local Downloading via the PC-Link

tiate Local Downloading via the PC-Link

tiate Local Downloading via the PC-Link

tiate Local Downloading via the PC-Link, enter [

][8]

[Installer Code] [499] [Installer Code] [499]. All keypads
will be busy for the duration of the PC-Link connection.
The status LEDs will display the current system status on
the keypad where the PC-Link was initiated. For more
information on connecting the PC-Link, refer to your ’PC-
Link Download Kit Instruction Sheet’.
Downloading can also be performed through the
LINKS1000 cellular communicator if the telephone line is
disconnected. If using the LINKS1000 with Call Back, you

need to program the LINKS1000 Preamble 

LINKS1000 Preamble 

LINKS1000 Preamble 

LINKS1000 Preamble with the

downloading telephone number in order for the panel to
call the computer correctly.

NOTE: 

When uploading labels from LCD keypads, the DLS

software will receive the labels only from the LCD keypad
assigned to slot 8. In addition, version 1.0 and version 2.0
LCD keypads are not compatible on the same system. For
more information refer to the Download Manual included
with the computer software.

NOTE: 

The most recent version of the PKP-LCD keypad on

the system should be assigned to slot 8.

Answering Machine Double Call Timer  . . . . . . . . . . . Section [405] 
Download Computer Telephone Number   . . . . . . . . . Section [402] 
Download Access Code . . . . . . . . . . . . . . . . . . . . . . . Section [403] 
Panel Identifier. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [404] 
LINKS1000 Preamble (Downloading)  . . . . . . . . . . . . . Section [490]

NOTE: 

To perform downloading via the T-Link module,

Option [1], Section 401 must be enabled or the number of
rings in section 406 must be programmed. 

NOTE: 

Option [2] applies to DLS via T-Link as well. Options

[3] and [4] cannot be performed through T-Link.

[402] - Downloading Computer’s Telephone Number

This telephone number is 32 digits in length. 

[403] - Downloading Access Code

This 4-digit Hexadecimal code allows the panel to con-
firm that it is communicating with a valid downloading
computer.

[404] - Panel Identification Code 

This 4-digit Hexadecimal code allows the downloading
computer to confirm the identity of the control panel.

[405] - Double-Call Timer

This timer sets the amount of time that can be taken
between calls when using Double Call to contact the
panel.
Valid entries are 001 to 255 (seconds).

[406] - Number of Rings to Answer On

The value in this section determines how many rings that
the panel will automatically pick up on in order to estab-

lish a DLS connection. Default value is 000 rings. Valid
entries are [000]-[020].

NOTE: 

If Section [401] Option 1 and Section [406] are

enabled, either one will work depending on how the
installer calls the premises.

[490] - LINKS DLS Phone Number Preamble 

Refer to Section [390].

[499] - Initiate PC-LINK Communications

The installer may initiate a PC-Link DLS session between
a computer and panel by entering this section in the fol-
lowing manner:
[499] - [Installer Code] [499].
The installer should already have the PC-Link cable prop-
erly connected between the panel’s header and the down-
loading computer as well as have the DLS file waiting for
the panel to connect before entering this command.

NOTE: 

PC-Link cannot be initiated while the panel is com-

municating via the phone line.

[401] - First Downloading Option Codes

Option

Downloading Code

On/Off

Description

1

Downloading Answer

ON

Downloading Answer Enabled.

 The system will answer calls for downloading if a successful 

Double call routine is detected. Have the downloading computer call the system and let the tele-
phone line ring once or twice. After 1 or 2 rings, hang up. If called back within the programmed 
Double Call Time (000-255 seconds), the panel will answer on the first ring.

OFF

Downloading Answer Disabled.

 The system will not answer incoming calls using the Double 

Call routine unless the User enables the DLS window. This option can be enabled by turning 
Option 2 ON.

2

DLS Window

ON

User Can Enable DLS Window.

 The user can use the [*][6][Master Code][5] command to 

enable a 6-hour window in which the panel will answer calls for downloading if a successful 
Double Call routine is detected. If this option is enabled, the window is open upon power-up. 
The window is on for the full 6 hours if enabled.

OFF

User Can Not Enable DLS Window.

 The user can not enable a window for DLS calls.

NOTE: Options 1 and 2 are not related. One does not need to be enabled for the other 
to perform its function.

3

Call-Back

ON

Call-Back Enabled

. When the system answers the downloading computer’s call, both the com-

puter and the panel will hang up. The panel will then call the Downloading Telephone Number 
and connect with the computer at that number. If more than one downloading computer is to 
be used, this function should be disabled.

OFF

Call-Back Disabled.

 The downloading computer will have immediate access to the panel once 

it is identified as a valid system.

4

User Call-Up

ON

User Call-Up Enabled.

 When this feature is enabled, the user may initiate a single call of the 

Downloading Telephone by entering [*][6][Master Code][6].

OFF

User Call-Up Disabled.

 An error tone will be generated when [*][6][Master Code][6] is 

entered.

5-8

For Future Use

Summary of Contents for PC1555 CP-01

Page 1: ...on on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be carefully read PC1555 CP 01 Version 3 2 DLS2002...

Page 2: ...NOTES...

Page 3: ...ned according to the SIA specification for Contact ID If Automatic Contact ID is enabled see Appendix A for reporting codes that will be used for each zone type Keypad Buzzer When enabled and the syst...

Page 4: ...d Bell Time Out for the system 009 011 5 3 Programmable Outputs Access to PGM Output programming for the main board PC5208 and PC5204 modules Output Attributes in Section in Sections 501 514 Assignmen...

Page 5: ...Decimal Data 9 3 3 Programming Hexadecimal Data 9 3 4 Programming Toggle Options 9 3 5 Viewing Programming 10 Section 4 Keypad Commands 11 4 1 Arming and Disarming 11 4 2 Commands 12 4 3 Function Keys...

Page 6: ...v PC1555 CP 01 Wiring Diagram NOTE Remove CON1 when using PGM2 for 2 wire smoke...

Page 7: ...system master 2 supervisor codes 2 duress 1 maintenance and 1 installer code Expandable to 32 zones Keypads with zone inputs available PC5516Z PC5532Z LCD5500Z LCD5520Z and LCD5501Z Wireless expansio...

Page 8: ...ule requires a 16 5 volt AC 40 VA transformer and 4Ah battery see PC5200 Installation Instructions for details PC5204 Power Supply Output Module The PC5204 can provide up to 1 Amp of additional power...

Page 9: ...ow current output module Dimensions 146mm x 105mm x 25 5mm 5 75 x 4 2 x 1 approximately CMC 1 CMC 1 CMC 1 CMC 1 alternate main control cabinet Commercial Burglary Dimensions 222mm x 298mm x 78mm 11 3...

Page 10: ...he Programming Worksheets should be filled out completely before attempt ing to program the system Step 10 Testing the System Test the panel completely to ensure that all features and functions are op...

Page 11: ...Power Non Power Limited All wiring entry points are designated by the arrows All circuits are classified UL installation power limited except for the battery leads which are not power limited A minimu...

Page 12: ...ys on each keypad may be pro grammed for different operation 1 Enter Installer Programming 2 Press 000 for Keypad Programming 3 Enter 1 to 5 to select function key to program 4 Enter a 2 digit number...

Page 13: ...lly Closed NC Loops To enable normally closed loops programming section 013 option 1 must be ON NOTE This option should only be selected if Normally Closed NC devices contacts are being used Normally...

Page 14: ...or for remotely connecting to the Escort5580 TC module via the LINKS1000 NOTE When using the LINKS1000 Busy Tone Detection must not be used NOTE Keypad zones cannot be used for 24 hr Supervisory or LI...

Page 15: ...y box This is handy if you only need to change the first few program boxes All other locations in the Section will remain unchanged If the key is pressed the panel will turn OFF the Ready light turn O...

Page 16: ...Emergency keys Fire Auxiliary or Panic to advance to the next digit When all the digits in a section have been viewed the panel will exit the section the Ready light will turn OFF and the Armed light...

Page 17: ...at any time by entering 1 see section 1 Zone Bypassing or by using the Away function button If a delay zone is violated during the Exit Delay i e somebody leaves through the designated entry exit doo...

Page 18: ...3 as OFF to ensure that Troubles are displayed correctly The various Troubles are described below Light Trouble 1 Service Required Press 1 to determine the specific Trouble Lights 1 8 will light up t...

Page 19: ...e Escort if installed Attribute 5 Attribute 5 Attribute 5 Attribute 5 For Future Use Attribute 6 Attribute 6 Attribute 6 Attribute 6 For Future Use Attribute 7 Attribute 7 Attribute 7 Attribute 7 Bell...

Page 20: ...exit Keypad Buzzer Control Keypad Buzzer Control Keypad Buzzer Control Keypad Buzzer Control When this option is selected the keypad will allow you to scroll through 21 different keypad sounder tone...

Page 21: ...System Master Code or Partition Master Code must be entered before the panel will allow User Functions to be performed section 4 2 Commands 13 7 1 Command Output Option 1 This function key provides th...

Page 22: ...76 Option 8 Automatic Scrolling of Alarms in Memory The LCD5500Z LCD5520Z keypad allows automatic scrolling through alarms in memory while the keypad is idle This feature if enabled will override the...

Page 23: ...2 205 Assigning Zones to System 555 560 Main Board PC5208 PC5208 Sect 6 Communicator Programming 561 564 PC5204 301 304 Telephone Numbers Para 5 9 International Programming 310 System Account Code 700...

Page 24: ...user then has another 30 second delay before the bell output latches and communications is activated A code is then required to silence the bell output NOTE The Fire Delay will be terminated if a 2nd...

Page 25: ...the Exit Delay or the Away function key is used the Interior Delay Zone will be active at the end of the Exit Delay This zone will cause an instant alarm when violated This zone type will fol low the...

Page 26: ...used to reset power for latching smoke detectors The output will deactivate for five seconds when the 7 2 command is entered see section 7 Command Output Functions The keypad buzzer will not sound fo...

Page 27: ...the PGM1 terminal for operation with the LINKS1000 cellular alarm communicator 17 Away Armed Status This output will activate when the system is armed with the Stay Away zones activated 18 Stay Armed...

Page 28: ...E This option must be OFF if PKP LCD keypads older than version 2 00 are used 4 Tampers Faults Dis play ON Tampers and Faults Do Not Show as Open The panel will not illuminate the respective zone LED...

Page 29: ...red 015 THIRD SYSTEM OPTION CODES Option Definition On Off Description 1 F Key ON F Key Enabled Pressing and holding the F key for 2 seconds will generate a Fire alarm The key pad will sound a set of...

Page 30: ...ng 5 Keypad Backlight ing ON Keypad Backlighting is Enabled All keypads on the system will have backlighting on all of the time OFF Keypad Backlighting is Disabled 6 Power Save Mode ON Power Save Mode...

Page 31: ...ted This feature is to prevent the bell from being activated when arming from inside the premises OFF Bell Squawk on all Arming Disarming Bell Squawks will be heard on all types of arming and dis armi...

Page 32: ...ow zone is open on the sys tem or not This Option is OFF at default 5 Keypad Buzzer Alarm ON Keypad Buzzer Follows Bell Enabled The keypad buzzers will follow the bell activity OFF Keypad Buzzer Follo...

Page 33: ...ately transmit If a second zone alarm occurs in the time period minutes pro grammed in this section the panel will log and trans mit the Police Code event If the second zone alarm occurs after this ti...

Page 34: ...o differentiation between the No Activity Pre alert and the Standard Auto arm Pre alert at a keypad No Activity Arming and Auto arm will log and transmit as a Special Closing 5 5 Partition Zone Progra...

Page 35: ...orting code program it as FF default setting or 00 For a complete description of reporting codes which can be programmed and lists of Automatic Contact ID and SIA format codes see section Appendix A R...

Page 36: ...h the Maintenance Code Stay Function Key arming Late to Close Late to Close Late to Close Late to Close A Late to Close Late to Close Late to Close Late to Close reporting code will be transmitted if...

Page 37: ...er back it will call the central station and transmit the reporting code to indicate a download session is about to begin DLS Lead Out DLS Lead Out DLS Lead Out DLS Lead Out After a downloading sessio...

Page 38: ...tions Section 351 to 376 Pager Format The Communicator Format Communicator Format Communicator Format Communicator Format option for either telephone number can be programmed for Pager format If an ev...

Page 39: ...condition if the telephone line is disconnected If the TLM Enable TLM Enable TLM Enable TLM Enable option is ON the panel will check the telephone line every 10 seconds If the telephone line volt age...

Page 40: ...d before a Telephone Line Trouble is generated is programmed here Valid entries are 000 255 for Trou ble annunciation and transmission LINKS delays of 10 to 2550 Seconds 42 5 Minutes Test Transmission...

Page 41: ...the Third Telephone Number fail a Failure to Communicate Trouble will be generated 7 LINKS Dialing ON Call LINKS as well as Land Line s The control panel will dial the programmed number of attempts th...

Page 42: ...hen transmitting to the central station OFF Contact I D Uses Automatic Reporting Codes The Contact I D communications format will use the automatic reporting codes as shown in Appendix C when transmit...

Page 43: ...f DAT and DATA The LINKS1000 Special Preamble is sent BEFORE the Preamble programmed in Sections 390 to 392 Example Special Preamble Regular Preamble Telephone Number NOTE If this Special Preamble is...

Page 44: ...ng Double Call to contact the panel Valid entries are 001 to 255 seconds 406 Number of Rings to Answer On The value in this section determines how many rings that the panel will automatically pick up...

Page 45: ...e Calculate the average amount of time per day that the panel gains or loses Add or subtract this value seconds from 60 and enter the value Example panel loses an average of 9 seconds per day Instead...

Page 46: ...try to place the call again following the Delay Between Dialing Attempts p OFF Busy Tone Detection Disabled The communicator will use the standard dialing procedure for every attempt 7 Battery Curren...

Page 47: ...To perform a Walk Test do the following 1 Enter Installer Programming 2 Enter Section 901 When any zone is violated the panel will activate the Bell Output for two seconds and log the event to the ev...

Page 48: ...nel Escort5580 TC mod ule PC5132 wireless expander module PC5400 printer module and LINKS2X50 module NOTE Defaulting the main panel does not default the keypads See the Programming Worksheets Appendic...

Page 49: ...to activate an audible Trouble signal within 90 seconds upon loss of microprocessor memory Programming The notes in the programming sections describing the system configura tions for UL Listed instal...

Page 50: ...BV 00 328 Burglary Not Verified This reporting code will be sent after the Burglary Verified Timer expires after a zone alarm occurs A R 3 78 BG 00 328 Alarm Cancelled This reporting code will be sen...

Page 51: ...l station on Phone 1 or 2 after FTC MA R 3 54 YK 00 347 Event Buffer is 75 Full Event buffer is almost full since last upload MA R 6 23 JL 00 347 DLS Lead In Downloading session start MA R 4 11 RB 00...

Page 52: ...r 1 59 Low Temp 1 32 Interior 1 61 Loss of Air Flow 1 33 24 hr Zone Definition SIA Auto Rep Codes Contact ID Auto Rep Codes Zone Alm Rest Zone Alm Rest Delay 1 BA ZZ BH ZZ 1 3A Delay 2 BA ZZ BH ZZ 1 3...

Page 53: ...f devices that may be connected to a line as determined by the total RENs contact the local Telephone Company For products approved after July 23 2001 the REN for this product is part of the product i...

Page 54: ...e complete system should be tested weekly and immediately after a break in an attempted break in a fire a storm an earthquake an accident or any kind of construction activity inside or outside the pre...

Page 55: ...NOTES...

Page 56: ...5108 v2 x No PC5132 v1 X Yes No support for Wireless Keys Pendants or Handheld Keypads PC5132 v2 X Yes PC5132 v3 X Yes PC5200 Yes PC5204 Yes PC5208 Yes PC5320 Yes PC5400 Printer DVACS Mod ule v1 X to...

Reviews: