1.1 Specifications

Control Panel Specifications

Flexible Zone Configuration:

• Six fully programmable zones
• Seven Access Codes: five User, one Master and a

second Master code

• Normally Closed, Single EOL, Double EOL
• 23 Zone Types, 6 Programmable Zone Options

Audible Alarm Output:

• Supervised Bell Output (current limited at 3 amps), 12 V

DC

• Steady or Pulsed Output

EEPROM Memory: 

Does not lose programming or

system status on complete AC and Battery failure

Programmable Outputs:

• Two Programmable Voltage Outputs, 20

programmable options
-  One High Current (300 mA) PGM output on main

panel

-  One Low Current (50 mA) PGM output on main

panel

Powerful 1.5 Amp Regulated Power Supply:

• 550 mA Auxiliary Supply, 12 V

DC

• Positive Temperature Coefficient (PTC) components

replace fuses

• Supervision for loss of AC Power, Low Battery
• Internal Clock Locked to AC Power Frequency

Power Requirements:

• Transformer = 16.5 VAC, 40VA
• Battery = 12 volt 4 Ah minimum rechargeable sealed

lead acid

Remote Keypad Specifications:

• Three Different Keypads Available:

- PC5506T 6 Zone LED Keypad
- LCD5500T Alphanumeric Keypad
- PC1575RK 6 Zone LED Keypad

• The PC5506T and LCD5500T keypads have 5 Fully

Programmable Function Keys and Tampers

• Connect up to 8 Keypads
• Four Wire (Quad) Connection to KEYBUS
• Built in Piezoelectric Buzzer

Digital Communicator Specifications:

• Supports Major Formats including SIA, Scantronics 4-8-1

Slot and Contact ID

• Event Initiated Personal Paging
• Three Programmable Phone Numbers
• Two Account numbers
• DTMF and Pulse Dialing
• DPDT Line Seizure
• Anti-jam Feature
• Split Reporting of Selected Transmissions to Each

Telephone Number

System Introduction

S

E

C

T

I

O

N

1

System Supervision Features

The PC1580 continuously monitors a number of possible
trouble conditions including:

• AC Power Failure
• Trouble by Zone
• Tamper by Zone
• Fire Trouble
• Telephone Line Trouble
• Failure to Communicate
• Low Battery Condition
• Bell Output Trouble
• Module Fault (Supervisory or Tamper)
• Loss of Internal Clock
• AUX Power Supply Fault

False Alarm Prevention Features

• Audible Exit Delay
• Audible Exit Fault
• Communication Delay
• Urgency on Entry Delay
• Quick Exit

Additional Features

• Auto Arm at Specified Time
• Keypad Activated Alarm Output and Communicator

Test

• All modules connect to the system via a four wire

KEYBUS up to 1000’/330m from main panel

• Event Buffer can be printed using PC5400 RS232 Serial

Interface module

• Supports the ESCORT 5580 Voice Prompt Module with

Automation/Lighting Control

• An Event Buffer which records the past 100 events with

both the time and date at which they occured

• Uploading and Downloading capability
• Local Downloading capability with the use of the

PC-LINK Adaptor

• Time compensation feature

1.2 Additional Devices

1.2.1 Keypads

A maximum of eight keypads can be connected to the
control panel and can be any combination of the following
listed.

• PC5506T 

6 zone LED keypad with function keys and

tamper

• LCD5500T 

LCD keypad with function keys and tamper

• PC1575RK 

6 zone LED keypad

1.2.2 ESCORT5580 Module

There are many benefits to adding the ESCORT5580 module
to a security system. The ESCORT5580 module will turn any
touch tone phone in the world into a fully functional keypad.
Imagine the security a customer would feel if they had the
ability to arm, disarm and check status of their alarm system
while at the office or on vacation.

Summary of Contents for PC1580BABT

Page 1: ...d Transmissions to Each Telephone Number System Introduction S E C T I O N 1 System Supervision Features The PC1580 continuously monitors a number of possible trouble conditions including AC Power Fai...

Page 2: ...s as well as surveillance costs thus improving the overall security protection For more information regarding the Downlook Video Transmission Module please consult the DLM 1 DLM 4 Installation Manuals...

Page 3: ...he various programmable features which options are available and how they function The Programming Worksheets pages 25 33 should be filled out completely before attempting to program the system Step 1...

Page 4: ...estrictions apply to KEYBUS wiring KEYBUS should be run in minimum 22 gauge quad 0 5mm two pair twist is preferred The modules should be home run to the panel but can be connected in series or T tappe...

Page 5: ...ons There are several different ways in which zones may be wired depending on which programming options have been selected Please refer to the following diagrams to study each type of individually sup...

Page 6: ...MINIMUM 18 AWG WIRING IS REQUIR FOR RESIDENTIAL FIRE ALARM SYST TO ZONE Z TERMINAL PROGRAMMED FOR FIRE TO ANY COM TERMINAL A U X B E L L 1 P G M 2 2 8 5 Keyswitch Zone Wiring If PGM2 has been program...

Page 7: ...ass interior zones manually When the system is armed using a valid user code if any zones on the system have been programmed as Stay Away zones the Bypass light will turn ON The panel will then monito...

Page 8: ...ill be ON When using an LCD keypad the trouble conditions will be listed on the display the user must simply use the arrow keys to scroll through the list of present trouble conditions The various tro...

Page 9: ...ccess code 1 One Master Code Access codes 2 to 6 Five User Codes All access codes have the ability to arm or disarm the system and can activate the PGM Outputs using the 7 1 Access Code and 7 2 comman...

Page 10: ...e the arrow keys to scroll to the desired contrast level and press the key to exit Keypad Beeper Control The LCD keypad will allow you to select from 21 different keypad beeper tones Use the arrow key...

Page 11: ...in Function Keys Section 3 5 05 9 No Entry Delay Arm Once this function key is pressed the user must enter a valid user code The system will arm and remove the entry delay from the system when the ex...

Page 12: ...amming Decimal Data A set number of programming boxes are allotted for each section requiring decimal data e g codes telephone numbers If a digit is entered for each program box the panel will automat...

Page 13: ...one Light 4 8 Add up the values for the zone lights to determine the number displayed for example no zone lights 0 all 4 zone lights 15 HEX F Press any of the Emergency Keys Fire Auxiliary or Panic to...

Page 14: ...ll cause an instant alarm if it is violated when the panel is armed Typically this zone is used for windows patio doors or other perimeter zones 04 Interior Zone This zone will not cause an alarm if v...

Page 15: ...hime This attribute determines whether or not the zone will activate the chime feature see Section 3 4 4 Door Chime On Off Bypass Enable This attribute determines whether or not the zone can be manual...

Page 16: ...es The panel can be programmed to report events to the central station by sending the Reporting Code programmed for a particular event Reporting codes can be one or two digits and can use HEX digits A...

Page 17: ...e Alarm Reporting Code during short power outages the panel will not send the signal unless AC power is lost for the amount of minutes programmed for the AC Failure Communication Delay The AC Failure...

Page 18: ...rmats 1 The digit 0 will send no pulses and is used as a filler 2 When programming account numbers enter four digits When programming a three digit account number the fourth digit must be programmed a...

Page 19: ...ing If the Downloading Answer option is enabled or during the first six hours after power up the panel will answer calls for downloading when the programmed Number of Rings is heard by the panel If th...

Page 20: ...24 Hour Latching Zones This output will activate for alarm conditions only Pre alerts or delays will not activate the output This output should only be activated for all audible alarms or medical con...

Page 21: ...porting Codes Section 44 TLM Trouble Delay Section 62 Option 1 5 12 Siren Supervision The panel supervises the Bell output If an open condition is detected or if the fuse is blown the panel will immed...

Page 22: ...il the exit delay expires The keypad will beep rapidly for the last 10 seconds of exit delay to warn the user that the system is about to arm For commercial applications the Bell Squawk on Exit Delay...

Page 23: ...eys are pressed for 30 seconds The keys however will remain backlit The panel will turn the lights back on when any key is pressed or when the entry delay begins or if an audible alarm occurs Keypad B...

Page 24: ...following 1 Enter the Installer s Programming mode 2 Enter the appropriate programming section XY 3 Enter the Installer s Code 4 Re enter the appropriate programming section XY The panel will take a f...

Page 25: ...eypad 3 I___________________________ __________________I I______________________________________ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Page 26: ...I________I I________I I________I I________I KEYPAD 6 I________I________ I I________I I________I I________I I________I I________I KEYPAD 7 I________I________ I I________I I________I I________I I______...

Page 27: ...Trouble Output 28 Silent 24 Hour PGM2 Only 09 Entry Delay Follower 29 Audible 24 Hour PGM2 Only 10 Exit Delay Follower 11 TLM and Alarm 12 Police Code Follower 07 Keypad Lockout Options Section 5 20 K...

Page 28: ...Y Y N N Y Y Y Y Y Y Y Y Y Y N Option 3 Chime N Y Y Y N N N N N N N N N N N N N N N N N N N N Option 4 Force N N N N N Y Y N N N N N N N N N N N N N N N N Y Option 5 Bypass N Y Y Y Y Y Y N N Y Y N N N...

Page 29: ...Codes I_______I_______ I Zone 1 I_______I_______ I Zone 4 I_______I_______ I Opening After Alarm I_______I_______ I Zone 2 I_______I_______ I Zone 5 I_______I_______ I Zone 3 I_______I_______ I Zone 6...

Page 30: ...orting Codes Section 5 7 Communicator Reporting Codes I_______I_______ I Phone Number 1 Failure to Communicate I_______I_______ I General Zone Fault Alarm I_______I_______ I Phone Number 2 Failure to...

Page 31: ...programmed 5 6 OFF I_______I 6 Restorals on Bell Time out Restorals Follow Zones 5 7 2 61 Second Communicator Option Code Default Option ON OFF Section OFF I_______I 1 Closing Confirmation Enabled Cl...

Page 32: ...n 5 9 Downloading Default 1580 I_______I_______I______ _ I _ ______I Enter 4 Hexadecimal Digits 74 Panel Identification Code Section 5 9 Downloading Default 1580 I_______I_______I______ _ I _ ______I...

Page 33: ..._______I 2 Handshake from Printer No Handshake OFF I________I 3 80 Column Printer 40 Column Printer OFF I________I 4 300 Baud Enabled Disabled OFF I________I 5 1200 Baud Enabled Disabled ON I________I...

Page 34: ...cksum bad 3 A4 ROM checksum bad 3 A5 System Reset 3 A6 Panel prog changed 3 A7 Self test failure 3 A8 System Shutdown 3 A9 Battery Test Failure 3 1A Ground Fault Sounder Relay Troubles 3 2A Sounder Re...

Page 35: ...XX 24 Hr Emergency Zone Alarm Restore QA XX QH XX 24 Hr Sprinkler Zone Alarm Restore SA XX SH XX 24 Hr Water Zone Alarm Restore WA XX WH XX 24 Hr Freeze Zone Alarm Restore ZA XX ZH XX 24 Hr Latching T...

Page 36: ...nue from Step 2 until all Labels are programmed 01 to 06 Zone Labels 14 Characters Default to 33 Fire Alarm Label 14 Characters 34 System Label 14 Characters Default Default 40 Utility Output Label 14...

Page 37: ...ys disabled OFF I_______ I 4 8 For Future Use 65 Fourth User Display Mask Default Option ON OFF ON I_______ I 1 User Initiated Call up Prompt ON User Initiated Call up Prompt OFF ON I_______ I 2 Last...

Page 38: ...for persons with criminal intent to develop techniques which reduce the effectiveness these features It is important that a security system be reviewed periodically to ensure that its featu remain ef...

Page 39: ...Panel Wiring Diagram TM Incorrect connections may result in fuse failure or improper operation Inspect wiring and ensure connections are correct before applying power Do not route any wiring over circ...

Page 40: ...PROVED for connection to telecommunication systems specified in the instructions for use subject to the conditions set out in them S 5054 3 W 504203 DSC PC1580 REN 1 5 London office DSC Security Produ...

Page 41: ...N G This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be carefully read...

Page 42: ...the integral modem or call setup equipment to contravene the requirements of the standards for approval as designated All apparatus connected to this equipment and thereby connected directly or indire...

Page 43: ...5 2 7 Removing Modules 5 2 8 Zone Wiring 5 2 8 1 Normally Closed NC Loops 5 2 8 2 Single End Of Line EOL Resistors 5600 5 2 8 3 Double End of Line DEOL Resistors 5 2 8 4 Fire Zone Wiring Four Wire Smo...

Page 44: ...nd Sur Gard 4 8 1 Communications Format 18 5 8 2 Pulse Formats 18 5 8 3 Contact ID 18 5 8 4 SIA 18 5 8 5 Pager Format 19 5 9 Downloading 19 5 10 PGM Output Options 19 5 11 Telephone Line Monitor TLM 2...

Reviews: