28
G E T T I N G S T A R T E D
P R O G R A M M I N G W O R K S H E E T S
[10] Third System Option Code
Default
Option
ON
OFF
Section
OFF
I________I
1
Arm / Disarm Bell Squawk Enabled
Arm / Disarm Bell Squawk Disabled
5.15
OFF
I________I
2
Bell Squawk During Auto Arm
No Bell Squawk During Auto Arm
5.16
OFF
I________I
3
Bell Squawk On Exit Delay
No Bell Squawk On Exit Delay
5.16
OFF
I________I
4
Bell Squawk On Entry Delay
No Bell Squawk On Entry Delay
5.16
ON
I________I
5
Audible Exit With Urgency
Silent Exit Delay
5.16
ON
I________I
6
Quick Arm Enabled
Quick Arm Disabled
3.4
[11] Fourth System Option Code
Default
Option
ON
OFF
Section
OFF
I________I
1
For Future Use
ON
I________I
2
Event Buffer Follow Swinger Shutdown Event Buffer Never Shuts Down
5.19
ON
I________I
3
Trouble Light Flashes If AC Fails
Trouble Light Does Not Flash If AC Fails
3.4
OFF
I________I
4
Exit Delay Termination Enabled
Exit Delay Termination Disabled
5.16
OFF
I________I
5
Keypad Blanking Enabled
Keypad Blanking Disabled
5.21
OFF
I________I
6
Keypad Tampers Enabled
Keypad Tampers Disabled
5.23
Zone Attribute Defaults
Option 1 – Audible / Silent
N
Y
Y
Y
Y
Y
Y
Y
Y
N
Y
Y
Y
N
Y
Y
Y
Y
Y
Y
Y
Y
Y
N
Option 2 – Steady / Pulsed
N
Y
Y
Y
Y
Y
Y
N N
Y
Y N N
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
N
Option 3 – Chime
N
Y
Y
Y
N
N
N N N
N
N N N
N N
N
N N
N N
N N N
N
Option 4 – Force
N
N N
N N
Y
Y
N N
N
N N N
N N
N
N N
N N
N N N
Y
Option 5 – Bypass
N
Y
Y
Y
Y
Y
Y
N N
Y
Y N N
N N
N
N N
N N
N
Y
Y
N
Option 6 – Downlook
N
N N
N N
N
N N N
N
N N N
N N
N
N N
N N
N N N
N
Y = Option ON
N = Option OFF
00
N
u
ll Zone (
N
ot
U
s
ed)
01
De
la
y
1
02
De
la
y
2
03
In
st
ant
04
In
te
rio
r
05
In
te
rio
r, S
ta
y
/A
w
a
y
06
De
la
y,
St
a
y
/A
wa
y
07
D
e
la
yed
24h
r Fi
re
08
St
a
n
dar
d
24
hr
F
ire
10
24hr
Super
v
is
or
y Buzzer
11
24hr
Bur
g
la
ry
12
24hr
H
eat
13
24hr
G
a
s
14
24hr
H
o
ld
-u
p
24
15
24hr
M
e
di
cal
16
24hr
Pani
c
17
24hr
Em
er
gency
18
24hr
Spr
in
kl
er
19
24hr
W
a
te
r
2
20
24hr
Fr
eeze
3
21
24hr
Lat
chi
ng T
a
m
p
er
22
In
te
rio
r D
e
la
y
23
Hour
Bel
l/
Buz
z
e
r
24
Push t
o
Set
Zone 1-6 Attributes
(Section 5.3 “Zone Attributes”)
OPT. 1
OPT. 2
OPT. 3
OPT. 4
OPT. 5
OPT. 6
ON
Audible
Steady
Chime
Force
Bypass
Downlook
OFF
Silent
Pulsed
No
No
No
No
[21]
Zone 1
I________|
I________|
I________|
I________|
I________|
I________I
[22]
Zone 2
I________|
I________|
I________|
I________|
I________I
I________I
[23]
Zone 3
I________|
I________|
I________|
I________|
I________I
I________I
[24]
Zone 4
I________|
I________|
I________|
I________|
I________I
I________I
[25]
Zone 5
I________|
I________|
I________|
I________|
I________I
I________I
[26]
Zone 6
I________|
I________|
I________|
I________|
I________I
I________I
Advanced System Programming
P R O G R A M M I N G W O R K S H E E T S