Trouble
Cause
Troubleshooting
Trouble [5] Zone Fault (Cont.)
One or more wireless devices have not
checked in within the programmed time
•
If the trouble occurs immediately, a conflict with a hard wired
zone exists:
•
The zone being used is already assigned to a PC5108 zone
expander
•
The zone being used is assigned as a keypad zone
•
Perform a Module Placement Test – Program Section [904] and
verify the wireless device is in a good location.
•
If bad test results occur, test the wireless device in another
location
•
If the wireless device now tests good, the original mounting
location is bad
•
If the wireless device continues to give bad test results
replace the wireless device
A short circuit is present on one or more
zones with double end-of-line resistors
enabled
•
Remove the wire leads from Z and COM terminals and measure
the resistance of the wire leads.
•
A short circuit indicates a short in the wiring.
•
Connect a 5.6K resistor (Green, Blue, Red) across the Z and
COM terminals.
•
Verify the trouble condition clears.
Trouble [6] Zone Tamper Press [6] to determine specific zones with a tamper trouble
A tamper condition is present on one or
more wireless devices
•
Perform a Module Placement Test –Section [904]
•
Violate, then restore the tamper:
•
If no test result then replace wireless device
An open circuit is present on one or more
zones with double end-of-line resistors
enabled
•
Remove the wire leads from Z and COM terminals.
•
Measure the resistance of the wire leads.
•
Open circuit indicates a break in the wiring.
•
Connect a 5.6K resistor (Green, Blue, Red) across the Z and
COM terminals.
•
Verify the trouble condition clears.
Trouble [7] Wireless Device Low Battery Press [7] to toggle through specific devices with low battery trouble
1st press
– Wireless Zones
2nd press
– Handheld Keypads
3rd press
– Wireless Keys
One or more wireless devices has a low
battery
NOTE: The event will not be logged to
the event buffer until the wireless device
low battery delay time expires
•
Program Section [377] Opt 9
Replace battery
NOTE: Replacing batteries will cause a tamper. Replacing cover will
restore the tamper causing the associated reporting codes to be sent
to the Central Station.
Trouble [8] Loss of Clock/Date
The main panel internal clock is not set
To program the time and date:
•
Enter [
✱
][6][Master Code] then Press [1]
•
Enter the time and date (in military) using the following format:
HH:MM MM/DD/YY
Example.
For 6:00 pm, June 29, 2005
Enter: [18] [00] [06] [29] [05]
IMPORTANT!
Ensure you have the following information available before contacting Customer Support
- Control Panel Type and Version, (e.g., PC1864 v4.1)
NOTE: Version number can be accessed by entering [
✱
][Installer Code][900] on any LCD keypad. This informa-
tion is also located on a sticker on the Printed Circuit Board.
- List of modules connected to Control Panel, (e.g., PC5400, PC5204 etc.)