PowerSeries - PC1616/PC1832/PC1864
Appendix E: Template Programming
Template programming allows quick programming of the minimum functions required for basic operation. The below tables are used to deter-
mine the desired template to be used ( for information on performing template programming see
Section 4 – Programming Descriptions
). Each
digit represents 1 of the template sections listed below. The option number selected for each digit will make up the 5 digit template programming
code.
•
Digit 1
selects Zone 1-8 definition options.
•
Digit 2
selects system EOL configuration options.
•
Digit 3
selects panel communications options.
Option
Zn1
Zn2
Zn3
Zn4
Zn5
Zn6
Zn7
Zn8
1 Delay 1
1
1
3
3
3
4
4
4
4
2 Delay 2
2
1
3
3
5
5
5
5
8
3 Instant
3
1
3
3
5
5
5
5
7
4 Interior
4
1
1
3
3
3
3
3
3
5 Interior Stay/Away
5
1
3
3
6
5
5
5
5
6 Delayed Stay/Away
6
1
3
3
6
5
5
5
8
7 Delayed 24-Hour Fire
Refer to Section 4 for Zone definition details
8 Standard 24-Hour Fire
Option
[013] Opt 1
[013] Opt 2
1
NC loops
ON
OFF
2
SEOL
OFF
OFF
3
DEOL
OFF
ON
Op#
Phone Line 1
Programming Section
Phone Line 2
Programming Section
1
Disabled
[380] Opt 1 OFF
Disabled
[380] Opt 1 OFF
2
SIA automatic Reporting Codes enabled
[350] 1st Phone # [04]
[380] Opt 1 ON
[381] Opt 3 OFF
SIA automatic
Reporting Codes
enabled
[350] 2nd Phone # [XX]
3
Contact ID Reporting Codes enabled
[350] 1st Phone # [03]
[380] Opt 1 ON
[381] Opt 7 OFF
SIA automatic
Reporting Codes
enabled
[350] 2nd Phone # [XX]
4
SIA automatic Reporting Codes enabled
[350] 1st Phone #[04]
[380] Opt 1 ON
[381] Opt 3 OFF
Residential Dial
Enabled
[350] 2nd Phone # [06]
5
Contact ID Reporting Codes enabled
[350] 1st Phone # [03]
[380] Opt 1 ON
Opt 7 OFF
Residential Dial
Enabled
[350] 2nd Phone # [06]
6
Contact ID Reporting Codes enabled
[350] 1st Phone # [03]
[380] Opt 1 ON
[381] Opt 7 OFF
Contact ID
Reporting Codes
Enabled
[350] 2nd Phone # [03]
WWW.DIYALARMFORUM.COM