10 BPS and 20 BPS Formats
10 BPS is the standard slow format used on Silent Knight / Ademco receivers.
DATA = 1900 Hz; KISS-OFF = 1400 Hz; SPEED = 10 baud
20 BPS is the standard fast format used on the DCI / Franklin / Sescoa and Vertex receivers.
DATA = 1800 Hz; KISS-OFF = 2300 Hz; SPEED = 20 baud
Radionics Format
For conventional Radionics 3/1 format, the communications mode should be set on either Radionics rounds (format
[09]) or Radionics parity (format [10]). The extended version of the Radionics format is normally used. The following
guidelines are provided to help in configuring the PC2585 for Radionics format.
1
The customer account code must be only 3 digits with a zero making up the fourth digit (i.e. Enter 1230 to program
an account code of 123).
2
The zone alarm reporting codes must all be single digit numerical codes with no extended second round being
sent (i.e. Zone 1 = 10, Zone 2 = 20... Zone 6 = 60). The zero in the second digit position tells the PC2585 not to
send an extended round.
3
All other non-alarm reporting codes must be set up to send an extended second round. The first digit of the
reporting code is used to identify the event while the second or extended digit is used to associate the event with
a particular item (i.e. A reporting code of E3 means restore zone 3. E = restore, 3 = zone 3).
4
The following is a list of first digit identifiers that should be used with the Radionics format.
• Restorals “E”. For example, E3 = restore zone 3
• Openings “B”. For example, B2 = opening by user 2
• Closings “C”. For example, C4 = closing by user 4
• Troubles “F”. For example, F5 = trouble from source 5
• Miscellaneous “D”. For example, D1 = partial closing
Sescoa Super Speed Format
The Sescoa Super Speed Format must be programmed exactly as follows in order to function correctly.
1
The account code must be four decimal digits in length and in the range of 0001 to 3374.
2
The reporting codes must be 2 digits in length and programmed as follows:
Alarms Zones 1 - 8 (Section [07] and [09])
A1 to A8
Restorals Zones 1 - 8 (Section [08] and [10])
A1 to A8
All Opening Codes (Sections [13] and [14])
BA
All Closing Codes (Sections [11] and [12])
CA
Partial Closing (Section [11])
C1
Low Battery (Section [16])
E1
Battery Restorals (Section [17])
E1
AC Failure (Section [16])
E1
AC Restoral (Section [17])
E1
Bell circuit Trouble (Section [16])
F1
Bell circuit Restoral (Section [17])
F1
Troubles (Sections [16] and [17])
AA
Priority Alarms (Section [15])
A1 to 99
Test Code (Section [17])
1C or DC
Opening After Alarm (Section [14])
B1
Auto-arm Abort Code (Section [12])
C8
Slot Format
Refer to Section [07] Alarm Reporting Codes, Zones 1 - 8 on page 19 for information on using the Slot Format.