30
[017]
Option
2
Auto-Arm Schedule Pro-
gramming
ON
Auto-arm Schedule in [*][6].
The Auto-Arm Schedules (Sect [181] - [188]) are accessible
via [*][6] as well as Installer’s Programming.
NOTE:
Refer to “Setting Date and Time” in the User’s Guide.
OFF
Auto-arm Schedule in Installer’s. Programming Only.
The Auto-Arm Schedules (Sect
[181] - [188]) are only accessible via Installer’s Programming.
NOTE:
This toggle controls access for all eight partitions
[017]
Option
3
Audible RF Jam Trouble
Beeps
ON
Audible RF Jam Trouble Beeps
OFF
An RF Jam will not sound Trouble Beeps
[017]
Option
4
Double Hit
ON
Double Hit Enabled
. Two alarms from the same zone within the Cross Zone Timer Dura-
tion will cause the Police Code or Cross Zone to be logged and transmitted.
OFF
Double Hit Disabled.
Two alarms from the same zone will not cause the Police Code or
Cross Zone to be logged and transmitted. Two different zones must be in alarm to trans-
mit the Police Code or verify the Cross Zone.
NOTE:
This feature only applies to zones defined as Interior, Interior Delay, Interior Stay/
Away, or Delay Stay/Away (PIR Zones).
• This is a flexible extension of the existing Police Code.
• This feature is directly affected by the Cross Zone Timer.
[017]
Op 5
Late To Close
ON
Late to Close Enabled.
The panel will communicate and log a Late to Close event at the
time programmed for Auto-Arm for each partition. This system toggle
controls if the Late
to Close Reporting Code is sent at the end of the Auto-arm/Postpone Pre-alert. Use this
feature for installations that require an audible warning if the panel is not armed by a cer-
tain time of day, but do not wish to have it arm. Anyone who hears this warning should
manually arm, or contact the Central Station to let them know why the panel has not
been armed by the programmed time.
OFF
Late to Close Disabled.
The panel will neither communicate nor log a Late to Close
event at the time programmed for Auto-Arm for each partition.
NOTE:
If the auto-arm toggle option is disabled, the Auto-arm Pre-alert will still occur if
there is a time programmed for that day if this option is enabled. This option does not
directly affect the functionality of auto-arm. If Late to Close is enabled and Auto-arming is
not, LCD Keypads will still display “System Arming in Progress” during the Late to Close
Pre-alert.
[017]
Option
6
Daylight Savings Time
ON
Daylight Savings Time Enabled.
At 2 a.m. on the first Sunday in April, the panel clock
will be set forward one hour to 3 a.m. At 2 a.m. on the last Sunday in October, the panel
clock will be set back one hour to 1 a.m. Events programmed to occur between 2:00 and
3:00 am. will not occur on the first Sunday in April. Events programmed to occur between
1:00 and 2:00 am. will occur twice on the last Sunday in October.
OFF
Daylight Savings Time Disabled.
The panel will make no automatic time adjustments
for Daylight Savings time.
NOTE:
Auto-arm and Test Transmissions should not be attempted between 0200 and
0300 hours, as they will be missed on the first Sunday in April. Events programmed to
occur between 0100 and 0200 will occur twice on the last Sunday in October.
[017]
Option
7
Periodic Camera Test
ON
Periodic Camera Test Enabled.
The panel will test all active cameras on the PC5108L
every 30 minutes.
OFF
Periodic Camera Test Disabled.
If this option is OFF, the panel will only test all active
cameras on the PC5108L upon exiting Installers’ Programming, or during System Test
NOTE:
The active camera monitor is selected using function key 22. Refer to the PC5108L
Installation Manual for function key use.
[017]
Option
8
Bell Squawk on Away Arm-
ing
ON
Squawk on Away Arming/Disarming Only
. Bell Squawks will only be heard on Away
Arming, as well as upon Disarming after being armed in the Away Mode.
NOTE:
This option controls when Bell Squawks are annunciated. This feature is to prevent
the Bell from being activated when arming from inside the premises.
OFF
Bell Squawk on all Arming/Disarming.
Bell Squawks will be heard on all types of Arm-
ing and Disarming.
NOTE:
This option follows the “Bell Squawk on Arming/Disarming” and “Bell Squawk
Attribute” features. This option is off at default.
Section
Option
On/Off
Description