background image

operated device may be connected between the positive supply voltage
and the ‘P/Z’ terminal (maximum load is 50mA).

NOTE: For UL Residential Fire Installations use at least one additional DSC

compatible keypad in conjunction with an RFK55XX-433 keypad or install

the RFK55XX-433 keypads within 3 feet from the control unit and mechan-

ically protect the keybus wires

Applying Power

Once all wiring is complete, and the equipment is secured to the building
structure with at least two screws apply power to the control panel:
1.  Connect the battery leads to the battery.
2.  Connect the AC transformer. 
For more information on control panel power specifications, see the control
panel Installation Manual.

Programming the Keypad

There are several programming
options available for the keypad.
These are described below. Pro-
gramming the keypad is similar
to programming the rest of the
system. When you are in the key-
pad programming sections, the
keypad will display which
options are turned on along the
top of the display.  To turn an
option on or off, press the num-
ber corresponding to the option
on the number pad. The numbers of the options that are currently turned
ON will be displayed.  For example, if options 1 and 4 are on, the display
will look like diagram shown on the different keypad displays.

 

For information on programming the rest of your security system, please
refer to your system’s Installation Manual.

Broadcasting LCD Labels

All LCD programming is done per keypad. If more than one LCD keypad is
present on the system, labels programmed at one keypad can be broadcast
to all other LCD keypads. Perform the following procedure in order to broad-
cast labels:
Step 1 - Program one LCD keypad completely.
Step 2 - Make sure all LCD keypads are connected to the Keybus.
Step 3 - Enter keypad programming by pressing [

,

][8][Installer

Code][

,

], then enter section [998] at the keypad that was programmed.

The keypad will now broadcast all the information programmed to all the
other LCD keypads on the system.
Step 4 - When the keypad is finished press the [#] key to exit.

NOTE: LCD Label broadcast from this keypad is only compatible

with other PK5500 and RFK5500 Keypads.

Language Programming

 

(PK5500\RFK5500 Only)

Hold (<>) keys for 2 seconds to enter language programming, scroll to
the desired language and Press [

,

] to select.

NOTE: If section [077] option 4 is OFF, language programming

can only be performed while in installers programming.

Enrolling the Keypad

The keypad will need to be assigned to a partition and slot if supervision or
keypad zones are being used.  Keypad assignments and keypad option pro-
gramming must be done at each keypad individually.
The 1st digit of keypad assignment is used to determine partition assign-
ment (1 to 8).  If partitioning is not used, enter [1].  For Global Keypads,
enter [0].

NOTE: LED and ICON keypads cannot be programmed as Global Keypads

The 2nd digit of keypad assignment is used to determine slot assignment
for keypad supervision.  Each keypad will be assigned a different slot num-
ber from 1 to 8.  PK5500 and RFK5500 LCD keypads come defaulted in slot
8.  If LCD keypads are used one LCD keypad must remain in slot 8.

NOTE: The RFK55XX enrolls as two modules:

Light 1 = keypad section of the RFK55XX

Light 17 = receiver section of the RFK55XX

NOTE: Deleting all wireless devices from the RFK55XX or defaulting the

RFK55XX will cause a supervisory fault.

Enter the following at each keypad installed on the system:
1. Enter Installer Programming by pressing [

,

][8][Installer’s Code]

2.  Press [000] for Keypad Programming
3.  Press [0] for Partition and Slot Assignment
4.  Enter the 1st digit (0 to 8 for partition assignment)
5.  Enter the 2nd digit (1 to 8 for slot assignment supervision)
6. Press the [#] key twice to exit programming.
7. After assigning all keypads, perform a supervisory reset by entering

[

,

][8][Installer’s Code][902] and wait for 60 seconds.

8. Press the [#] key to exit programming after 60 seconds.

Programming Labels

 

(PK5500\RFK5500 Only)

1. Enter keypad programming by pressing [

,

][8][Installer Code][

,

]. Enter

the 3-digit section number for the label to be programmed.

2. Use the arrow keys (<>) to move the underline bar underneath the let-

ter to be changed. 

3.

Press the number keys [1] to [9] corresponding to the letter you require.
The first time you press the number the first letter will appear. Pressing the
number key again will display the next letter

.

4. When the required letter or number is displayed use the arrow keys

(<>) to scroll to the next letter.

5. When you are finished programming the Zone Label, press the [

,

] key,

scroll to “Save,” then press [

,

].

6. Continue from Step 2 until all Labels are programmed.

ASCII Characters

Changing Brightness/Contrast

LCD Keypads

1. Press [

,

][6][Master code].

2. Use the [<][>] keys to scroll to either Brightness Control or Contrast Control.
3. Press [

,

] to select the setting you want to adjust.

4. a) ‘Brightness Control’: There are multiple backlighting levels. Use the [<][>]

keys to scroll to the desired level.
b) ‘Contrast Control’: There are 10 different display contrast levels. Use the
[<][>] keys to scroll to the desired contrast level.

5. To exit, press [#].

LED/ICON Keypads

1. Press [

,

][6][Master Code].

2. Use the [>] key to move through the 4 different backlighting levels.
3. The level is automatically saved when you press [#] to exit.

Changing the Buzzer Level

LCD Keypads

1. Press [

,

][6][Master Code].

2. Use the [<][>] keys to scroll to Buzzer Control.
3. There are 21 different levels, use the [<][>] keys to scroll to the desired level.
4. To exit, press [#].

LED/ICON Keypads

1. Press [

,

][6][Master Code].

2. Use the [<] key to move through the 21 different buzzer levels.
3. The level is automatically saved when you press [#] to exit.

Broadcasting Door Chime

All door chime programming is done per keypad. If more than one keypad is
present on the system, door chime programmed at one keypad can be broad-
cast to all other keypads. Perform the following procedure in order to broadcast
door chime:
Step 1 - Program one keypad completely.
Step 2 - Make sure all keypads are connected to the Keybus.
Step 3 - Enter keypad programming by pressing [

,

][8][Installer Code][

,

], then

enter section [994] at the keypad that was programmed. The keypad will
now broadcast all the door chime information programmed to all the
other  keypads on the system.

Step 4 - When the keypad is finished press the [#] key to exit.

4

1

Toggle Option

1 _  _  4  _  _  _  _ 

[1]

 - A, B, C, 1

[4]

 - J, K, L, 4

[7]

 - S, T, U, 7

[0]

 - Space

[2]

 - D, E, F, 2

[5]

 - M, N, O, 5

[8]

 - V, W, X, 8

[3]

 - G, H, I, 3

[6]

 - P, Q, R, 6

[9]

 - Y, Z, 9,0

Summary of Contents for Power PK55 Series

Page 1: ...sistema para obener informaci n sobre las limitaciones del uso y funciones del producto as como las limitaciones de la responsabilidad del fabricante NOTA Estas instrucciones deber n utilizarse conju...

Page 2: ...outs Connect Keybus andPGM Zone wiring to keypad Place tamper switch into tamper hole on backplate 4 Remove keypad from hooks Place keypad into backplate ensure the wire is pushed back into the wall a...

Page 3: ...in slot 8 If LCD keypads are used one LCD keypad must remain in slot 8 NOTE The RFK55XX enrolls as two modules Light 1 keypad section of the RFK55XX Light 17 receiver section of the RFK55XX NOTE Dele...

Page 4: ...the user s authority to operate this equipment FCC Compliance Statement Caution Changes or modifications not expressly approved by Digital Security Controls could void your authority to use this equip...

Page 5: ...ime On Off 14 Command Output 2 23 Bypass Recall 32 Partition 8 Select 07 System Test 15 Global Stay Arm 24 Bypass Group Recall 33 Local PGM Activate Available only on the PC1616 PC1832 PC1864 version...

Page 6: ...indicates AC absent ON I____I 7 Alarms always Displayed When Armed Alarms not Displayed When Armed OFF I____I 8 Low Temperature Warning Enabled Low Temperature Warning Disabled Section Partition Label...

Page 7: ...he cover to the backplate The tamper is restored and the zone sends a battery trouble restoral signal to the receiver The battery trouble is now clear and the device should function normally NOTE When...

Page 8: ...Key 13 I __ _ __ I __ __ _ I_ __ _ _I _ __ __ I __ _ __ I_ _ __ _ I 46 Key 6 I __ _ __ I __ __ _ I_ _ __ _I _ __ _ _I __ _ __ I __ __ _ I 54 Key 14 I __ _ __ I __ __ _ I_ __ _ _I _ __ __ I __ _ __ I_...

Reviews: