background image

Keypad Enrollment

Enter keypad programming by pressing [

,

][8][Installer’s Code][000].

[0] Partition / Slot Assignment

[1]-[5] Function Key Assignment

Keypad Function Keys

Refer to your system installation manual for a complete list of all function key options available for your system.

Keypad Programming

Enter keypad programming by pressing [

,

][8][Installer Code][

,

]

[001]-[064] Zone Label 1 to 64 

(PK5500\RFK5500 Only)

ex. For Zone 1 enter section [001], for Zone 2 enter section [002] etc. Default: “Zone 1”  - “Zone 64”

[065] Fire Alarm Label 

(28 Characters) (PK5500\RFK5500 Only)

Default:“Fire Zone”

[066] Fail to Arm Event Message

 (PK5500\RFK5500 Only)

Default: “System Has Failed to Arm”

[067] Alarm When Armed Event Message 

(PK5500\RFK5500 Only)

Default: “Alarm Occurred While Armed < >”

[071]  First User Display Mask

[072] Second User Display Mask

[073] Download LCD Message Duration

 

(PK5500\RFK5500 Only)

Default: 003 

 I_____I_____I_____I  

(Valid entries are 000-255), 000=Unlimited Message Disp.This 

number represents the number of times the Downloaded message is cleared by pressing any key while the 
message is up after timeout).

Digit

Option

Valid Range

Default

1st

Partition Assignment (0=Global Keypad)

0 to 8

1

I_____I

2nd

Slot Assignment

1 to 8

LED,ICON=1/LCD=8

I_____I

Function Key

Button

Valid Range Default

Function

[1] Function Key 1 Assignment

00 to 32

03

Stay Arm

I_____I_____I

[2] Function Key 2 Assignment

00 to 32

04

Away Arm

I_____I_____I

[3] Function Key 3 Assignment

00 to 32

06

Chime On/Off

I_____I_____I

[4] Function Key 4 Assignment

00 to 32

14

Sensor Reset

I_____I_____I

[5] Function Key 5 Assignment

00 to 32

16

Quick Exit

I_____I_____I

[00]

 - Null

[08]

 - Bypass Mode

[16]

 - Quick Exit

[26]

 - Time & Date Program

[01]

 - Partition 1 Select

[09]

 - Trouble Display

[17]

 - Activate Stay/Away

[27]

 - Partition 3 Select

[02]

 - Partition 2 Select

[10]

 - Alarm Memory

[18]

 - *Global Away Arm

[28]

 - Partition 4 Select

[03]

 - Stay Arm

[11]

 - User Programming

[19]

 - Command Output 3

[29]

 - Partition 5 Select

[04]

 - Away Arm

[12]

 - User Functions

[21]

 - Command Output 4

[30]

 - Partition 6 Select

[05]

 - No Entry Arm

[13]

 - Command Output 1

[22]

 - *Global Disarming

[31]

 - Partition 7 Select

[06]

 - Chime On/Off

[14]

 - Command Output 2 

[23]

 - Bypass Recall

[32]

 - Partition 8 Select

[07]

 - System Test

[15]

 - *Global Stay Arm

[24]

 - Bypass Group Recall

[33]

 - Local PGM Activate

*Available only on the PC1616/PC1832/PC1864 version 4.2 or higher.

Section

Zone

Label

[001] to [064] 1 to 64

I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I

I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I

[065]

I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I

I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I

[066]

I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I

I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I

[067]

I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I

I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I

Default

Option

ON

OFF

ON

I____I

1

Hold [P]anic Key prompt ON

Hold [P]anic Key prompt OFF

ON

I____I

2

Auto-arm Control/Time prompt ON

Auto-arm Control/Time prompt OFF

ON

I____I

3

Quick Arm prompt ON

Quick Arm prompt OFF

ON

I____I

4

Interior Arm prompt ON

Interior Arm prompt OFF

OFF

I____I

5

Quick Exit prompt ON

Quick Exit prompt OFF

OFF

I____I

6

Thermostat Control prompt ON

Thermostat Control prompt OFF

OFF

I____I

7

ACK All Trouble Prompt ON

ACK All Trouble Prompt OFF

OFF

I____I

8

Music Input prompt ON

Music Input prompt OFF

Default

Option

ON

OFF

ON

I____I

1

User-initiated Call-up prompt ON

User-initiated Call-up prompt OFF

OFF

I____I

2

For  Future  Use

OFF

I____I

3

Walk Test prompt ON

Walk Test prompt OFF

ON

I____I

4

Command Output#1 prompt ON

Command Output#1 prompt OFF

ON

I____I

5

Command Output#2 prompt ON

Command Output#2 prompt OFF

OFF

I____I

6

Command Output#3 prompt ON

Command Output#3 prompt OFF

OFF

I____I

7

Command Output#4 prompt ON

Command Output#4 prompt OFF

OFF

I____I

8

For  Future  Use

Summary of Contents for Power PK55 Series

Page 1: ...sistema para obener informaci n sobre las limitaciones del uso y funciones del producto as como las limitaciones de la responsabilidad del fabricante NOTA Estas instrucciones deber n utilizarse conju...

Page 2: ...outs Connect Keybus andPGM Zone wiring to keypad Place tamper switch into tamper hole on backplate 4 Remove keypad from hooks Place keypad into backplate ensure the wire is pushed back into the wall a...

Page 3: ...in slot 8 If LCD keypads are used one LCD keypad must remain in slot 8 NOTE The RFK55XX enrolls as two modules Light 1 keypad section of the RFK55XX Light 17 receiver section of the RFK55XX NOTE Dele...

Page 4: ...the user s authority to operate this equipment FCC Compliance Statement Caution Changes or modifications not expressly approved by Digital Security Controls could void your authority to use this equip...

Page 5: ...ime On Off 14 Command Output 2 23 Bypass Recall 32 Partition 8 Select 07 System Test 15 Global Stay Arm 24 Bypass Group Recall 33 Local PGM Activate Available only on the PC1616 PC1832 PC1864 version...

Page 6: ...indicates AC absent ON I____I 7 Alarms always Displayed When Armed Alarms not Displayed When Armed OFF I____I 8 Low Temperature Warning Enabled Low Temperature Warning Disabled Section Partition Label...

Page 7: ...he cover to the backplate The tamper is restored and the zone sends a battery trouble restoral signal to the receiver The battery trouble is now clear and the device should function normally NOTE When...

Page 8: ...Key 13 I __ _ __ I __ __ _ I_ __ _ _I _ __ __ I __ _ __ I_ _ __ _ I 46 Key 6 I __ _ __ I __ __ _ I_ _ __ _I _ __ _ _I __ _ __ I __ __ _ I 54 Key 14 I __ _ __ I __ __ _ I_ __ _ _I _ __ __ I __ _ __ I_...

Reviews: