background image

[074] Key Options

[076] First Keypad Options

[077] Second Keypad Options

[080] PGM Terminal 1

Default: 01  

 

I_______I _______I 

   

 

1-14 Follow PGM Output Number, 15 Local PGM Pulse , 16 Local PGM Toggle

[082] Local PGM Output Pulse Activation Time

Default: 00  

 

I_______I _______I 

   

Minutes (Valid Range 00-99)

Default: 05  

 

I_______I _______I 

   

Seconds (Valid Range 00-99)

[101]-[108] Partition Labels

 

(PK5500\RFK5500 Only)

ex. For Partition 1 enter section [101], for Partition 2 enter section [102] etc.

NOTE: Partition 1 Label is also used as the System Label

[120]-[151] Command Output Labels

 

(PK5500\RFK5500 Only)

Default: “Command_O/P_1” - “Command_O/P_4”

[201]-[264] Door Chime Sound Programming

You can program the keypad to make up to four different door chime sounds for individual zones.

ex. For Zone 1 enter section [201], for Zone 2 enter section [202] etc.

[994][

,

] Initiate Global Keypad Chime Broadcast

[995][

,

] Reset Keypad Options to Factory Default

[996][

,

] Label Default (PK5500\RFK5500 Only)

[997]  View Software Version (PK5500\RFK5500 Only)
[998][

,

] Initiate Global Label Broadcast (PK5500\RFK5500 Only)

[999][

,

] Reset Keypad EEPROM to Factory Defaults

Keypad Display Symbols

Default

Option

ON

OFF

ON

I____I

1

[F]ire Key Enabled

[F]ire Key Disabled

ON

I____I

2

[A]uxiliary Key Enabled

[A]uxiliary Key Disabled

ON

I____I

3

[P]anic Key Enabled

[P]anic Key Disabled

OFF

I____I

4-8 For Future Use

Default

Option

ON

OFF

ON

I____I

1

Display Code when Programming

Display “Xs” when Programming

ON

I____I

2

Local Clock Display ON

Local Clock Display OFF

OFF

I____I

3

Local Clock Displays 24-hr Time

Local Clock Displays AM/PM

ON

I____I

4

Auto Alarm Memory Scroll Enabled

Auto Alarm Memory Scroll Disabled

OFF

I____I

5

Local Display of Temperature ON

Local Display of Temperature OFF

ON

I____I

6

Bypass Options prompt ON

Bypass Options prompt OFF

OFF

I____I

7

For  Future  Use

OFF

I____I

8

Auto-Scroll Open Zones ON

Auto-Scroll Open Zones OFF

Default

Option

ON

OFF

ON

I____I

1

Chime Enabled for Zone Openings

Chime Disabled for Zone Openings

ON

I____I

2

Chime Enabled for Zone Closings

Chime Disabled for Zone Closings

OFF

I____I

3

5th Terminal is Keypad PGM Output

5th Terminal is Keypad Zone Input

ON

I____I

4

Language Selection 

Enabled

Language Selection 

Disabled

OFF

I____I

5

Power LED Enabled

Power LED Disabled

ON

I____I

6

Power LED indicates AC present

Power LED indicates AC absent

ON

I____I

7

Alarms always Displayed When Armed

Alarms not Displayed When Armed

OFF

I____I

8

Low Temperature Warning Enabled

Low Temperature Warning Disabled

Section

Partition

Label

[101] to [108] 1 to 8

I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I

I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I

For Partition 1 Command O/P 1 to 4 enter [120] to [123] For Partition 5 Command O/P 1 to 4 enter [136] to [139]
For Partition 2 Command O/P 1 to 4 enter [124] to [127] For Partition 6 Command O/P 1 to 4 enter [140] to [143]
For Partition 3 Command O/P 1 to 4 enter [128] to [131] For Partition 7 Command O/P 1 to 4 enter [144] to [147]
For Partition 4 Command O/P 1 to 4 enter [132] to [135] For Partition 8 Command O/P 1 to 4 enter [148] to [151]

Section Part

Cmd.

Output

Label

[120]-[151]1to8 1to4

I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I

I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I

Default

Option

ON

OFF

ON

I____I

1

6 Beeps

Disabled

OFF

I____I

2

“Bing-Bing” Sound

Disabled

OFF

I____I

3

“Ding-Dong” Sound

Disabled

OFF

I____I

4

Alarm  Tone

Disabled

OFF

I____I

5-8 For Future Use

8

Bypass –  Indicates that there are zones automatically or 
manually bypassed.

9

For Future Use

10

Arm Mode – Indicates the mode the panel is armed in.

Stay – Indicates that the panel is armed in the Stay 
Mode. It will turn on at the beginning of the Exit 
Delay

1

Fire –  Indicates that there are fire alarms in memory.

2

Memory –  Indicates that there are alarms in memory.

Away – Indicates that the panel is armed in the Away 
Mode. It will turn on at the beginning of the Exit 
Delay

3

Ready Light (green) –  If the Ready light is on, the system 
is ready for arming.

4

Armed Light (red) –  If the Armed light is on, the system 
has been armed successfully.

11

Chime – This icon turns on when Door Chime is enabled on 
the system and will turn off when Door Chime is disabled.

5

System Trouble –  Indicates that a system trouble is active.

12

Open – When zones are opened, this icon will turn on, and 
7 segment displays 1 and 2 will scroll through the open 
zones.

6

AC –  Indicates that AC is present at the main panel.

7

Program – Indicates that the system is in Installer’s Pro-
gramming, or the keypad is busy.

1

2

3

4
5
6

7

8

1

2

9

10

11

12

7

8

Summary of Contents for Power PK55 Series

Page 1: ...sistema para obener informaci n sobre las limitaciones del uso y funciones del producto as como las limitaciones de la responsabilidad del fabricante NOTA Estas instrucciones deber n utilizarse conju...

Page 2: ...outs Connect Keybus andPGM Zone wiring to keypad Place tamper switch into tamper hole on backplate 4 Remove keypad from hooks Place keypad into backplate ensure the wire is pushed back into the wall a...

Page 3: ...in slot 8 If LCD keypads are used one LCD keypad must remain in slot 8 NOTE The RFK55XX enrolls as two modules Light 1 keypad section of the RFK55XX Light 17 receiver section of the RFK55XX NOTE Dele...

Page 4: ...the user s authority to operate this equipment FCC Compliance Statement Caution Changes or modifications not expressly approved by Digital Security Controls could void your authority to use this equip...

Page 5: ...ime On Off 14 Command Output 2 23 Bypass Recall 32 Partition 8 Select 07 System Test 15 Global Stay Arm 24 Bypass Group Recall 33 Local PGM Activate Available only on the PC1616 PC1832 PC1864 version...

Page 6: ...indicates AC absent ON I____I 7 Alarms always Displayed When Armed Alarms not Displayed When Armed OFF I____I 8 Low Temperature Warning Enabled Low Temperature Warning Disabled Section Partition Label...

Page 7: ...he cover to the backplate The tamper is restored and the zone sends a battery trouble restoral signal to the receiver The battery trouble is now clear and the device should function normally NOTE When...

Page 8: ...Key 13 I __ _ __ I __ __ _ I_ __ _ _I _ __ __ I __ _ __ I_ _ __ _ I 46 Key 6 I __ _ __ I __ __ _ I_ _ __ _I _ __ _ _I __ _ __ I __ __ _ I 54 Key 14 I __ _ __ I __ __ _ I_ __ _ _I _ __ __ I __ _ __ I_...

Reviews: