15
4.4
Programming Toggle Option Sections
Some programming sections contain several toggle options.
The panel will use zone lights 1 through 8 to indicate if the dif-
ferent options are enabled or disabled. Press the number cor-
responding to the option to turn it ON or OFF. Once all the
toggle options have been selected correctly, press the [#] key
to exit the section and save the changes. The Ready light will
turn OFF and the Armed light will turn ON.
Refer to the Programming Worksheets in this manual to deter-
mine what each option represents and whether the light
should be ON or OFF for your application.
4.5
Viewing Programming
LED/Fixed Message LCD Keypads
Any programming section can be viewed from an LED key-
pad. When a programming section is entered, the keypad will
immediately display the first digit of information programmed
in that section.
The keypad displays the information using a binary format,
according to the following chart:
See Hex data
entry instructions
Press any of the Emergency keys (Fire, Auxiliary or Panic) to
advance to the next digit. When all the digits in a section have
been viewed, the panel will exit the section; the Ready light
will turn OFF and the Armed light will turn ON, waiting for the
next three-digit programming section number to be entered.
Press the [#] key to exit the section
LCD Keypad
When a programming section is entered, the keypad will
immediately display all the information programmed in that
section. Use the arrow keys (< >) to scroll through the data
being displayed. Scroll past the end of the data displayed or
press the [#] key to exit the section.